Literature DB >> 8770291

The functional hepatic volume assessed by 99mTc-GSA hepatic scintigraphy.

J Wu1, N Ishikawa, T Takeda, Y Tanaka, X Q Pan, M Sato, T Todoroki, R Hatakeyama, Y Itai.   

Abstract

The accuracy of measurement of the functional hepatic volume by single photon emission computed tomography (SPECT) with 99mTc-galactosyl serum albumin (99mTc-GAS) was evaluated. 99mTc-GSA planar scintigraphic images were obtained dynamically and the hepatic SPECT imaging was then performed in 25 patients with hepatobiliary tumors. The patients were divided into 4 groups with normal hepatic function, and mild, moderate and severe hepatic dysfunction. The functional hepatic volume determined by SPECT was compared with the morphological hepatic volume determined by compute tomography. The ratio of the hepatic volumes obtained by the two methods was calculated. The mean hepatic volume ratio was 96.6 +/- 2.3% in the normal hepatic function group and 95.9 +/- 2.2% in the mild dysfunction group (n.s.). In both the moderate and severe hepatic dysfunction groups, the hepatic volume ratio was smaller than that in the normal group (87.9 +/- 5.2%, p < 0.0001, and 71.9 +/- 7.6%, p < 0.0001, respectively). There was a linear correlation between the hepatic volume ration and various indices of reserve hepatic function, such as LHL15 (r = 0.83, p < 0.0001), HH15(r = 0.74, p < 0.0001), and ICG15 (r = 0.75, p < 0.0005). These results indicate that the hepatic volume ratio is proportional to the severity of hepatic dysfunction, and suggest that the functional hepatic volume measured with 99mTc-GSA faithfully reflects the functioning hepatocyte mass. 99mTc-GSA scintigraphy and hepatic SPECT therefore provide information regarding global and regional reserve hepatic function.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8770291     DOI: 10.1007/bf03168406

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  19 in total

1.  Functional hepatic imaging with receptor-binding radiopharmaceutical: clinical potential as a measure of functioning hepatocyte mass.

Authors:  M Kudo; A Todo; K Ikekubo; M Hino; Y Yonekura; K Yamamoto; K Torizuka
Journal:  Gastroenterol Jpn       Date:  1991-12

2.  Measurement of liver volume by emission computed tomography.

Authors:  M K Kan; G B Hopkins
Journal:  J Nucl Med       Date:  1979-06       Impact factor: 10.057

3.  Accurate measurement of liver, kidney, and spleen volume and mass by computerized axial tomography.

Authors:  S B Heymsfield; T Fulenwider; B Nordlinger; R Barlow; P Sones; M Kutner
Journal:  Ann Intern Med       Date:  1979-02       Impact factor: 25.391

4.  [A simple method for estimation of liver volume using CT-scan after major hepatic resection].

Authors:  Y Une; K Ogasawara; T Kamiyama; K Misawa; S Matsuoka; Y Nakajima; J Uchino
Journal:  Nihon Geka Gakkai Zasshi       Date:  1993-07

5.  [Evaluation of a counting method for liver volume determination using single photon emission computed tomography].

Authors:  K Senda; K Tanaka; S Sakuma
Journal:  Kaku Igaku       Date:  1984-04

6.  Hepatic recognition and catabolism of serum glycoproteins.

Authors:  G Ashwell; C J Steer
Journal:  JAMA       Date:  1981-11-20       Impact factor: 56.272

7.  Determination of liver, kidney, and spleen volumes by computed tomography: an experimental study in dogs.

Authors:  A A Moss; M A Friedman; A C Brito
Journal:  J Comput Assist Tomogr       Date:  1981-02       Impact factor: 1.826

8.  Volume determinations using computed tomography.

Authors:  R S Breiman; J W Beck; M Korobkin; R Glenny; O E Akwari; D K Heaston; A V Moore; P C Ram
Journal:  AJR Am J Roentgenol       Date:  1982-02       Impact factor: 3.959

9.  [The utility of quantitative 99mTc-GSA liver scintigraphy in the evaluation of hepatic functional reserve: comparison with 99mTc-PMT and 99mTc-Sn colloid].

Authors:  N Shuke; T Aburano; K Nakajima; K Yokoyama; B F Sun; H Matsuda; A Muramori; T Michigishi; N Tonami; K Hisada
Journal:  Kaku Igaku       Date:  1992-05

10.  [Clinical evaluation of hepatic blood flow and liver function with 99mTc-DTPA-HSA].

Authors:  K Ono; H Kato; T Nishibe; T Tanabe; K Nagao; K Ito
Journal:  Nihon Geka Gakkai Zasshi       Date:  1993-08
View more
  6 in total

1.  Relationship between CT volumetry and functional liver volume using technetium-99m galactosyl serum albumin scintigraphy in patients undergoing preoperative portal vein embolization before major hepatectomy: a preliminary study.

Authors:  Atsushi Nanashima; Hiroyuki Yamaguchi; Shinichi Shibasaki; Shigeyuki Morino; Noboru Ide; Hiroaki Takeshita; Takashi Tsuji; Terumitsu Sawai; Tohru Nakagoe; Takeshi Nagayasu; Youji Ogawa
Journal:  Dig Dis Sci       Date:  2006-07       Impact factor: 3.199

2.  Liver regeneration in donors evaluated by Tc-99m-GSA scintigraphy after living donor liver transplantation.

Authors:  Masaki Kaibori; Sang Kil Ha-Kawa; Yoichiro Uchida; Morihiko Ishizaki; Takamichi Saito; Kosuke Matsui; Junko Hirohara; Koichi Tanaka; Yasuo Kamiyama
Journal:  Dig Dis Sci       Date:  2007-08-04       Impact factor: 3.199

3.  Preoperative assessment of congestive liver dysfunction using technetium-99 m galactosyl human serum albumin liver scintigraphy in patients with severe valvular heart disease.

Authors:  Hiroyuki Nishi; Toshiki Takahashi; Goro Matsumiya; Hiroshi Takano; Hajime Ichikawa; Shigeru Miyagawa; Yoshiki Sawa
Journal:  Surg Today       Date:  2007-06-26       Impact factor: 2.549

Review 4.  ICG Clearance Test and 99mTc-GSA SPECT/CT Fusion Images.

Authors:  Yuji Iimuro
Journal:  Visc Med       Date:  2017-11-22

5.  Hepatectomy in a case of hepatocellular carcinoma with constitutional indocyanine green excretory defect.

Authors:  Richi Nakatake; Morihiko Ishizaki; Chika Miyasaka; Kosuke Matsui; Masaki Kaibori
Journal:  Int J Surg Case Rep       Date:  2018-11-01

6.  Evaluation of patients who underwent percutaneous transhepatic portal vein embolisation by Tc-99m GSA scintigraphy.

Authors:  Norifumi Kennoki; Kiyoshi Koizumi; Koichi Tomita; Tomohisa Moriya; Jun Otaka; Kunihito Suzuki; Toru Saguchi; Naokazu Chiba; Shigeyuki Kawachi; Hiromi Serizawa
Journal:  Pol J Radiol       Date:  2018-12-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.