OBJECTIVE: This study compared the efficacy of a removable anterior mandibular positioning (AMP) device to continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA) using a fully balanced crossover design.
DESIGN: Twenty-three male subjects with confirmed OSA were recruited from the Technion Sleep Laboratory in Haifa, Israel, from February 18, 1991 to December 17, 1992. Twenty-one of the 23 subjects enrolled completed all aspects of the study.
RESULTS: The mean apnea-hypopnea index (AHI) before treatment was 33.86 +/- 14.30. The mean AHI decreased with CPAP to 59.50%, but decreased only 38.91% with the AMP device. The lowest mean recorded oxygen saturation level for the 21 subjects was 84.30 before treatment, 91.10 after CPAP treatment, and 90.20 after AMP treatment. Sleep data revealed a significant decrease in stage 1 and 2 (p=0.0088) and an increase in rapid eye movement percent (p=0.0066) for both treatments when compared with baseline. Three- to 10-month posttreatment phone interviews showed that 1 subject was not using either device, 1 subject was using CPAP, and 2 subjects were using the AMP device intermittently due to occasional temporomandibular joint pain symptoms. The remaining 17 subjects were all using the AMP device nightly. The symptoms of excessive daytime sleepiness also decreased significantly by both AMP and CPAP.
CONCLUSIONS: The AMP device achieved substantial success in most cases, but was less effective than CPAP, especially for the more severe cases. In general, the AMP device was strongly preferred over the CPAP by the subjects of this study.

Entities:  

Mesh:

Year:  1996        PMID: 8769497     DOI: 10.1378/chest.109.6.1477

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  36 in total

Review 1.  New developments in the treatment of obstructive sleep apnoea.

Authors:  A K Simonds
Journal:  Thorax       Date:  2000-08       Impact factor: 9.139

2.  Oral Appliance Therapy for the Management of Sleep Disordered Breathing: An Overview.

Authors:  Robert R. Rogers
Journal:  Sleep Breath       Date:  2000       Impact factor: 2.816

3.  Effect of Jaw and Head Position on Airway Resistance in Obstructive Sleep Apnea.

Authors:  Jae-Kap Choi; Michael Goldman; Sankar Koyal; Glenn Clark
Journal:  Sleep Breath       Date:  2000       Impact factor: 2.816

4.  Comparison of adjustable and fixed oral appliances for the treatment of obstructive sleep apnea.

Authors:  Christopher J Lettieri; Nathalie Paolino; Arn H Eliasson; Anita A Shah; Aaron B Holley
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

Review 5.  Oral appliances for obstructive sleep apnoea.

Authors:  J Lim; T J Lasserson; J Fleetham; J Wright
Journal:  Cochrane Database Syst Rev       Date:  2006-01-25

6.  Soft palate cephalometric changes with a mandibular advancement device may be associated with polysomnographic improvement in obstructive sleep apnea.

Authors:  Hong Joong Kim; Seung-No Hong; Woo Hyun Lee; Jae-Cheul Ahn; Min-Sang Cha; Chae-Seo Rhee; Jeong-Whun Kim
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-05-23       Impact factor: 2.503

7.  Treatment outcomes of mandibular advancement devices in positional and nonpositional OSA patients.

Authors:  Jin Woo Chung; Reyes Enciso; Daniel J Levendowski; Todd D Morgan; Philip R Westbrook; Glenn T Clark
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-03-17

8.  Sleep apnoea and its impact on public health.

Authors:  J Wright; T Sheldon
Journal:  Thorax       Date:  1998-05       Impact factor: 9.139

9.  Multidisciplinary management of the airway in a trauma-induced brain injury patient.

Authors:  Jacques R Conaway; Steven C Scherr
Journal:  Sleep Breath       Date:  2004-09       Impact factor: 2.816

10.  The tongue-retaining device: efficacy and side effects in obstructive sleep apnea syndrome.

Authors:  Diane S Lazard; Marc Blumen; Pierre Lévy; Pierre Chauvin; Dorothée Fragny; Isabelle Buchet; Frédéric Chabolle
Journal:  J Clin Sleep Med       Date:  2009-10-15       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.