Literature DB >> 8763283

Manual assessment of fracture stiffness.

J Webb1, G Herling, T Gardner, J Kenwright, A H Simpson.   

Abstract

A fracture stiffness of 15 Nm/degree measured biomechanically has been proposed as a reliable indicator of early fracture union. This study used a fracture model to examine the ability of orthopaedic surgeons to assess the stiffness of a fracture manually. Twenty orthopaedic surgeons were tested along with 20 controls. They each estimated the stiffness of seven rods representing mid-shaft diaphyseal fractures at different stages of healing, and were asked whether the stiffness suggested that union had progressed to the stage where the stabilizing device could be removed. Surgeons were unable to estimate the fracture stiffness accurately, and greatly overestimated rod stiffness particularly for the lower values. This meant that on 83 per cent of occasions when the stiffness was less than 15 Nm/degree, the surgeons considered the fracture models united to a sufficient degree to prescribe removal of the fixator. The results suggest that clinical assessment of fracture stiffness alone may put 83 per cent of patients at risk of refracture or malunion. Manual testing of the mechanical stability of a fracture appears not to be reliable.

Entities:  

Mesh:

Year:  1996        PMID: 8763283     DOI: 10.1016/0020-1383(96)00009-5

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  10 in total

1.  Utilizing Multiple BioMEMS Sensors to Monitor Orthopaedic Strain and Predict Bone Fracture Healing.

Authors:  Jakob G Wolynski; Conor J Sutherland; Hilmi Volkan Demir; Emre Unal; Akbar Alipour; Christian M Puttlitz; Kirk C McGilvray
Journal:  J Orthop Res       Date:  2019-05-17       Impact factor: 3.494

Review 2.  Variability in the assessment of fracture-healing in orthopaedic trauma studies.

Authors:  Luis A Corrales; Saam Morshed; Mohit Bhandari; Theodore Miclau
Journal:  J Bone Joint Surg Am       Date:  2008-09       Impact factor: 5.284

3.  Monitoring the mechanical properties of healing bone.

Authors:  L E Claes; J L Cunningham
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

4.  Real-Time Wireless Platform for In Vivo Monitoring of Bone Regeneration.

Authors:  Pablo Blázquez-Carmona; Manuel Sanchez-Raya; Juan Mora-Macías; Juan Antonio Gómez-Galán; Jaime Domínguez; Esther Reina-Romo
Journal:  Sensors (Basel)       Date:  2020-08-15       Impact factor: 3.576

5.  Diagnostic prediction of ovine fracture healing outcomes via a novel multi-location direct electromagnetic coupling antenna.

Authors:  Jakob G Wolynski; Kevin M Labus; Jeremiah T Easley; Branislav M Notaroš; Milan M Ilić; Christian M Puttlitz; Kirk C McGilvray
Journal:  Ann Transl Med       Date:  2021-08

6.  Direct electromagnetic coupling to determine diagnostic bone fracture stiffness.

Authors:  Jakob G Wolynski; Milan M Ilić; Kevin M Labus; Branislav M Notaroš; Christian M Puttlitz; Kirk C McGilvray
Journal:  Ann Transl Med       Date:  2022-05

7.  Scoring systems for early prediction of tibial fracture non-union: an update.

Authors:  George D Chloros; Nikolaos K Kanakaris; James S H Vun; Anthony Howard; Peter V Giannoudis
Journal:  Int Orthop       Date:  2021-06-15       Impact factor: 3.075

Review 8.  Current Options for Determining Fracture Union.

Authors:  Saam Morshed
Journal:  Adv Med       Date:  2014-09-14

9.  The Role of Ultrasound Imaging of Callus Formation in the Treatment of Long Bone Fractures in Children.

Authors:  Magdalena Wawrzyk; Jan Sokal; Ewa Andrzejewska; Przemysław Przewratil
Journal:  Pol J Radiol       Date:  2015-10-17

10.  The radiographic union scale in tibial (RUST) fractures: Reliability of the outcome measure at an independent centre.

Authors:  J M Leow; N D Clement; T Tawonsawatruk; C J Simpson; A H R W Simpson
Journal:  Bone Joint Res       Date:  2016-04       Impact factor: 5.853

  10 in total