Literature DB >> 8759089

Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography. A comparison with radionuclide angiography.

Y F Nosir1, P M Fioretti, W B Vletter, E Boersma, A Salustri, J T Postma, A E Reijs, F J Ten Cate, J R Roelandt.   

Abstract

BACKGROUND: Three-dimensional echocardiography is a promising technique for calculation of left ventricular ejection fraction, because it allows its measurement without geometric assumptions. However, few data exist that study its reproducibility and accuracy in patients. METHODS AND
RESULTS: Twenty-five patients underwent radionuclide angiography and three-dimensional echocardiography that used the rotational technique (2 degrees interval and ECG and respiratory gating). Left ventricular volume and ejection fraction were calculated by use of Simpson's rule at a slice thickness of 3 mm. Analyses were performed to define the largest slice thickness required for accurate calculation of left ventricular volume and ejection fraction. Three-dimensional echocardiography showed excellent correlation with radionuclide angiography for calculation of left ventricular ejection fraction (mean +/- SD, 38.9 +/- 19.8 and 38.5 +/- 18.0, respectively; r = .99); their mean difference was not significant (0.03 +/- 0.17; P = .3), and they had a close limit of agreement (-0.385, 0.315). Intraobserver variability for radionuclide angiography and three-dimensional echocardiography was 4.2% and 2.6%, respectively, whereas interobserver variability was 6.2% and 5.3%, respectively. There was no significant difference between left ventricular volume and ejection fraction calculated at a slice thickness of 3 mm and that calculated at different slice thicknesses up to 24 mm. However, the standard deviation of the mean difference showed a stepwise increase, particularly at thicknesses > 15 mm. At a slice thickness of 15 mm, the probability of three-dimensional echocardiography to detect > or = 6% difference in ejection fraction was 80%.
CONCLUSIONS: Three-dimensional echocardiography has excellent correlation with radionuclide angiography for calculation of left ventricular ejection fraction in patients and has an observer variability similar to that of radionuclide angiography. We recommend the use of a 15-mm-thick slice for accurate and rapid measurement of left ventricular volume and ejection fraction.

Entities:  

Mesh:

Year:  1996        PMID: 8759089     DOI: 10.1161/01.cir.94.3.460

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  12 in total

Review 1.  Central role of echocardiography in the diagnosis and assessment of heart failure. British Society of Echocardiography.

Authors:  M G Cheesman; G Leech; J Chambers; M J Monaghan; P Nihoyannopoulos
Journal:  Heart       Date:  1998-11       Impact factor: 5.994

2.  Extraction of the two-dimensional cardiothoracic ratio from digital PA chest radiographs: correlation with cardiac function and the traditional cardiothoracic ratio.

Authors:  Ronan F J Browne; Geraldine O'Reilly; David McInerney
Journal:  J Digit Imaging       Date:  2004-06       Impact factor: 4.056

3.  Clinical application of three-dimensional echocardiography: past, present and future.

Authors:  S A Kleijn; O Kamp
Journal:  Neth Heart J       Date:  2009-01       Impact factor: 2.380

4.  Echocardiographic and pathoanatomical characteristics of isolated left ventricular non-compaction: a step towards classification as a distinct cardiomyopathy.

Authors:  R Jenni; E Oechslin; J Schneider; C Attenhofer Jost; P A Kaufmann
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

5.  Accuracy of three-dimensional echocardiography in patients with prior anteroseptal myocardial infarction.

Authors:  Yoshiaki Maruyama; Kentaro Toyama; Shunichi Sato; Nobuyuki Masaki; Masato Kirimura; Nobuo Yoshimoto
Journal:  J Echocardiogr       Date:  2009-01-14

6.  Serial evaluation of myocardial function using the myocardial performance index in Kawasaki disease.

Authors:  Eun Song Song; Somy Yoon; Joo Hyun Cho; Eun Mi Yang; Hwa Jin Cho; Young Youn Choi; Jae Sook Ma; Gwang Hyeon Eom; Young Kuk Cho
Journal:  World J Pediatr       Date:  2018-03-12       Impact factor: 2.764

7.  Left atrial volume assessed by transthoracic three dimensional echocardiography and magnetic resonance imaging: dynamic changes during the heart cycle in children.

Authors:  T Poutanen; A Ikonen; P Vainio; E Jokinen; T Tikanoja
Journal:  Heart       Date:  2000-05       Impact factor: 5.994

8.  Left ventricular ejection fraction measurements: accuracy and prognostic implications in a large population of patients with known or suspected ischemic heart disease.

Authors:  Alessia Gimelli; Patrizia Landi; Paolo Marraccini; Rosa Sicari; Paolo Frumento; Antonio L'Abbate; Daniele Rovai
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-09       Impact factor: 2.357

Review 9.  Ultrasound imaging versus morphopathology in cardiovascular diseases: the heart failure.

Authors:  Giorgio Baroldi; Riccardo Bigi; Lauro Cortigiani
Journal:  Cardiovasc Ultrasound       Date:  2007-01-30       Impact factor: 2.062

Review 10.  Single photon emission computed tomography: an alternative imaging modality in left ventricular evaluation.

Authors:  Hulya Yalçin; Sofiane Maza; Fatih Yalçin
Journal:  Vasc Health Risk Manag       Date:  2008
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.