[Hemodynamic response to intubation with Macintosh and McCoy blades].

J Román1, B Beltrán de Heredia, P García-Velasco, F Parramón, R García, J Vilaplana, A Villalonga.   

Abstract

INTRODUCTION: The McCoy laryngoscope incorporates a modification of the Macintosh blade designed to facilitate laryngoscopy and difficult intubation. One end is articulated to allow better viewing of the larynx. Use of this blade reduces pressure placed on tissues in the supraglottic area during laryngoscopy.
OBJECTIVE: We designed this study to compare the hemodynamic repercussions of laryngoscopy and tracheal intubation (LTI) performed with either a Macintosh or the McCoy blade. PATIENTS AND
METHOD: Sixty ASA I-II patients scheduled for elective surgery requiring LTI were randomly assigned to 2 groups of 30 patients each. In both groups anesthetic induction was achieved with 0.04 mg.kg-1 midazolam, 0.002 mg.kg-1 fentanyl, 2 mg.kg-1 propofol and 0.1 mg.kg-1 vecuronium. In group 1 LTI laryngoscopy and intubation were performed using the Macintosh size 3 blade and in group 2 the McCoy size 3 blade was used. Systolic and diastolic arterial pressures and heart rate were recorded in each patient before anesthetic induction (baseline), 1 minute after induction and 5 minutes after start of LTI.
RESULTS: We found no significant differences between the 2 groups at any of the recording times.
CONCLUSION: The data obtained do not allow us to assert that there is any difference in hemodynamic response to LTI associated to type of blade used.

Entities:  

Mesh:

Year:  1996        PMID: 8753922

Source DB:  PubMed          Journal:  Rev Esp Anestesiol Reanim        ISSN: 0034-9356


  3 in total

1.  Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

Authors:  Nitesh Gill; Shobha Purohit; Poonam Kalra; Tarun Lall; Avneesh Khare
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec

2.  Randomized controlled study comparing the hemodynamic response to laryngoscopy and endotracheal intubation with McCoy, Macintosh, and C-MAC laryngoscopes in adult patients.

Authors:  Faiza Sulaiman Buhari; Venkatesh Selvaraj
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2016 Oct-Dec

3.  Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes.

Authors:  Mehtab A Haidry; Fauzia A Khan
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.