Literature DB >> 8748309

Comparison of four enzyme immunoassays for detection of human T-cell lymphotropic virus type 2 antibodies.

D Gallo1, E T Yeh, E S Moore, C V Hanson.   

Abstract

Four licensed enzyme immunoassay (EIA) kits for the measurement of antibody to human T-cell lymphotropic virus (HTLV) type 1, one from Organon Teknika Corp. (OTC), one from Cambridge Biotech Corp. (CBC), and two from Abbott Laboratories (the 1993 modification [Abb 93] and the 2.0 version licensed in 1995 [Abb 95]), were evaluated for sensitivity and specificity in the detection of HTLV type 2 antibody, and the results were compared with those previously obtained with earlier kit versions. The CBC, Abb 95, Abb 93, and OTC kits had sensitivities of 99.7, 97.6, 96.8, and 96.2%, respectively, compared with sensitivities of 89.1 and 60% for the Abbott and CBC (previously DuPont) kits, respectively, licensed in 1988. Thus, the abilities of commercial kits to detect HTLV antibody have improved. The relative specificities of the CBC, Abb 95, Abb 93, and OTC kits with negative blood donor specimens that had been reactive with the 1988 CBC EIA kit were 92.9, 64.5, 78.8, and 62.6%, respectively. Compared with those of the 1988 versions, the specificity of the Abbott EIA has decreased and the specificity of the CBC kit has been significantly improved.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8748309      PMCID: PMC228766          DOI: 10.1128/jcm.34.1.213-215.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  7 in total

1.  Comparison of six commercial human T-cell lymphotropic virus type I (HTLV-I) enzyme immunoassay kits for detection of antibody to HTLV-I and -II.

Authors:  C Cossen; S Hagens; R Fukuchi; B Forghani; D Gallo; M Ascher
Journal:  J Clin Microbiol       Date:  1992-03       Impact factor: 5.948

2.  Detection and differentiation of antibodies to human T-cell lymphotropic virus types I and II by the immunofluorescence method.

Authors:  D Gallo; L M Penning; C V Hanson
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

3.  Comparison of Western immunoblot antigens and interpretive criteria for detection of antibody to human T-lymphotropic virus types I and II.

Authors:  D Gallo; J L Diggs; C V Hanson
Journal:  J Clin Microbiol       Date:  1990-09       Impact factor: 5.948

4.  Sensitivities of radioimmunoprecipitation assay and PCR for detection of human T-lymphotropic type II infection.

Authors:  D Gallo; L M Penning; J L Diggs; C V Hanson
Journal:  J Clin Microbiol       Date:  1994-10       Impact factor: 5.948

5.  Development and evaluation of a human T-cell leukemia virus type I serologic confirmatory assay incorporating a recombinant envelope polypeptide.

Authors:  E P Lillehoj; S S Alexander; C J Dubrule; S Wiktor; R Adams; C C Tai; A Manns; W A Blattner
Journal:  J Clin Microbiol       Date:  1990-12       Impact factor: 5.948

6.  High prevalence of HTLV-II among intravenous drug abusers: PCR confirmation and typing.

Authors:  S Kwok; D Gallo; C Hanson; N McKinney; B Poiesz; J J Sninsky
Journal:  AIDS Res Hum Retroviruses       Date:  1990-04       Impact factor: 2.205

7.  Evaluation of two commercial human T-cell lymphotropic virus western blot (immunoblot) kits with problem specimens.

Authors:  D Gallo; J L Diggs; C V Hanson
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

  7 in total
  1 in total

1.  Human T-cell lymphotropic virus type 1 gag indeterminate western blot patterns in Central Africa: relationship to Plasmodium falciparum infection.

Authors:  R Mahieux; P Horal; P Mauclère; O Mercereau-Puijalon; M Guillotte; L Meertens; E Murphy; A Gessain
Journal:  J Clin Microbiol       Date:  2000-11       Impact factor: 5.948

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.