Literature DB >> 8747123

High-resolution light microscopy for interpretation of renal biopsies.

E O Hoffmann1.   

Abstract

Routine transmission electron microscopy is recommended for all renal biopsies. However, most of the diagnostic lesions in renal pathology are 0.2 micron or larger, and are therefore visible by light microscopy. These lesions are difficult to evaluate in paraffin sections due to problems inherent in the method itself. Full utilization of the resolving power of the light microscope or high-resolution light microscopy is possible with resin (plastic) histotechnology. The replacement of conventional histotechnology by epoxy histotechnology allows the visualization of most subcellular structures needed for accurate diagnosis in renal pathology. Electron microscopy remains a very helpful tool for selected morphological problems.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8747123     DOI: 10.1007/bf00868738

Source DB:  PubMed          Journal:  Pediatr Nephrol        ISSN: 0931-041X            Impact factor:   3.714


  38 in total

1.  "Adjacent" sections--a bridge in the gap between light and electron microscopy.

Authors:  J A Lynn
Journal:  Hum Pathol       Date:  1975-07       Impact factor: 3.466

2.  Comparison of the results of semi-thin sections with those of conventional paraffin histology and immunohistology in renal biopsy specimens.

Authors:  G Ditscherlein; W Schneider
Journal:  Int Urol Nephrol       Date:  1976       Impact factor: 2.370

3.  Use and interpretation of renal biopsy.

Authors:  G E Striker; L J Quadracci; R E Cutler
Journal:  Major Probl Pathol       Date:  1978

Review 4.  Electron microscopic study of medical diseases of the kidney: update--1988.

Authors:  F G Silva; C L Pirani
Journal:  Mod Pathol       Date:  1988-07       Impact factor: 7.842

5.  Preparation of percutaneous kidney biopsies for high resolution light microscopy.

Authors:  L Zamboni
Journal:  Hum Pathol       Date:  1972-03       Impact factor: 3.466

6.  Practical use of electron microscopy for the diagnosis of glomerular disease.

Authors:  B H Spargo
Journal:  Hum Pathol       Date:  1975-07       Impact factor: 3.466

7.  Glycol methacrylate embedding of renal biopsy specimens for light microscopy.

Authors:  L C Agodoa; G E Striker; E Chi
Journal:  Am J Clin Pathol       Date:  1975-11       Impact factor: 2.493

8.  The use of post-embedding immunoelectron microscopy in the diagnosis of glomerular diseases. Comparison of immunoelectron microscopic and immunofluorescence studies.

Authors:  F J Skjørten; S H Brorson; B Roald; E H Strøm; B Lund
Journal:  APMIS       Date:  1992-11       Impact factor: 3.205

9.  Polystyrene embedding: a new method for light and electron microscopy.

Authors:  G Frangioni; G Borgioli
Journal:  Stain Technol       Date:  1979-07

10.  Transmission electron microscopy and serial sections for light microscopy from the same block in routine renal pathology.

Authors:  E O Hoffmann; H B Garrett; J R Coover; T R Flores
Journal:  Am J Clin Pathol       Date:  1983-10       Impact factor: 2.493

View more
  1 in total

1.  Acp. Best practice no 160. Renal biopsy specimens.

Authors:  P N Furness
Journal:  J Clin Pathol       Date:  2000-06       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.