Dosimetric characterization of radiosurgical beams with a diamond detector.

S N Rustgi1, D M Frye.   

Abstract

Dosimetric characteristics of small diameter 6 MV photon beams for a commercial radiosurgery system have been measured in a solid water phantom with a new diamond detector and compared with measurements using a p-type Si photon diode, small volume cylindrical and parallel plate ionization chambers, and radiographic films. Tissue maximum ratios (TMR) and total scatter factors (S c.p) were measured with the three ionometric (diamond, diode, ion chamber) detectors for 12 circular beams ranging in diameter from 12.5 to 40 mm. The TMR values obtained with the three ionometric detectors agreed well (+/- 1%) for all cone sizes and depths investigated when the displacement of the sensitive volume of the detector from its front surface is taken into account. The S c.p factors obtained with the ionometric detectors also agreed well (+/- 1.2%) for field sizes greater than 20 mm in diameter. For smaller field sizes, the cylindrical and parallel plate chambers measure a smaller S c.p factor, as a result of the steep dose gradients across their sensitive volumes. Cross-beam profiles acquired with the diamond detector agree well with the measurements with the diode detector and radiographic film. A distortion in the measured profiles in terms of broadened penumbra is observed with a small volume cylindrical ionization chamber.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8746721     DOI: 10.1118/1.597655

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

2.  Monte carlo simulation of bony heterogeneity effects on dose profile for small irradiation field in radiotherapy.

Authors:  Simone C Cardoso; Victor Gabriel L Alves; Luiz Antonio R da Rosa; Luciana T Campos; Delano V S Batista; Alessandro Facure
Journal:  PLoS One       Date:  2010-05-03       Impact factor: 3.240

3.  Can clinically relevant dose errors in patient anatomy be detected by gamma passing rate or modulation complexity score in volumetric-modulated arc therapy for intracranial tumors?

Authors:  Shingo Ohira; Yoshihiro Ueda; Masaru Isono; Akira Masaoka; Misaki Hashimoto; Masayoshi Miyazaki; Masaaki Takashina; Masahiko Koizumi; Teruki Teshima
Journal:  J Radiat Res       Date:  2017-09-01       Impact factor: 2.724

4.  Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry.

Authors:  L A R da Rosa; S C Cardoso; L T Campos; V G L Alves; D V S Batista; A Facure
Journal:  J Appl Clin Med Phys       Date:  2010-01-28       Impact factor: 2.102

5.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep

6.  The impact of corrected field output factors based on IAEA/AAPM code of practice on small-field dosimetry to the calculated monitor unit in eclipse™ treatment planning system.

Authors:  Sammuel Mamesa; Sornjarod Oonsiri; Taweap Sanghangthum; Sumalee Yabsantia; Sivalee Suriyapee
Journal:  J Appl Clin Med Phys       Date:  2020-04-01       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.