Literature DB >> 8744335

Orientation-dependent visibility of long thin objects in polarization-based microscopy.

R Arimoto1, J M Murray.   

Abstract

Under conditions of directional illumination, the visibility of long, thin objects depends very strongly on the direction and polarization of the incident light. Solutions to Maxwell's equations for the case of an infinite cylinder in an electromagnetic field are well known, and have been used by others in the past for theoretical analysis of light scattering by long, thin objects. The existence of those solutions allows us to calculate the expected angular distribution and polarization of the light scattered from long, thin objects illuminated by a plane wave at any angle. In this paper we show for the first time how one can incorporate these solutions of Maxwell's equations into a quantitative description of the expected appearance of filamentous biological structures in polarization-based microscopy. Our calculations for unidirectional polarized illumination show that thin, dielectric linear objects such as microtubules (or shallow interfaces) observed with finite aperture optics 1) are totally invisible when the angle (phi) between the object's long axis and incident illumination is outside the range magnitude of 90 - phi < or = sin-1 [1.33/N.A.obj]degrees; and 2) are seen with maximum intensity when phi = 90 degrees for incident illumination and scattered light polarized, either both parallel or both perpendicular to the long axis of the object; whereas 3) two maxima appear at phi approximately equal to 90 +/- 25 degrees for polarization of the incident illumination parallel to, but the scattered light perpendicular to the long axis, or vice versa; and 4) in either of these latter conditions, the objects are invisible when the illumination is near normal incidence. These counterintuitive predictions were exactly borne out by our experimental measurements of light-scattering intensity from flagellar axonemes as a function of orientation in a polarizing microscope. These calculations and measurements provide a foundation for furthering our understanding of textural or form birefringence. Calculations based on a solid cylinder model accurately predict the shapes of the measured intensity versus orientation curves. However, the relative intensities of axonemes viewed with different polarizer-analyzer settings differ from those calculated for a homogeneous solid cylinder. Thus we find that these relative intensities can provide a sensitive probe for the structure of biological objects with diameters much smaller than the wavelength of light.

Entities:  

Mesh:

Year:  1996        PMID: 8744335      PMCID: PMC1225277          DOI: 10.1016/S0006-3495(96)79867-3

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  10 in total

1.  The movements of fibrocytes.

Authors:  E J AMBROSE
Journal:  Exp Cell Res       Date:  1961       Impact factor: 3.905

2.  A surface contact microscope for the study of cell movements.

Authors:  E J AMBROSE
Journal:  Nature       Date:  1956-11-24       Impact factor: 49.962

Review 3.  Total internal reflection fluorescence microscopy.

Authors:  D Axelrod
Journal:  Methods Cell Biol       Date:  1989       Impact factor: 1.441

Review 4.  Image fidelity: characterizing the imaging transfer function.

Authors:  I T Young
Journal:  Methods Cell Biol       Date:  1989       Impact factor: 1.441

5.  Electron microscopy of frozen hydrated eukaryotic flagella.

Authors:  J M Murray
Journal:  J Ultrastruct Mol Struct Res       Date:  1986 Apr-Jun

6.  Measuring diameters of rod-shaped bacteria in vivo with polarized light scattering.

Authors:  B V Bronk; S D Druger; J Czégé; W P Van de Merwe
Journal:  Biophys J       Date:  1995-09       Impact factor: 4.033

7.  Reactivation of sperm flagella: properties of microtubules-mediated motility.

Authors:  B H Gibbons
Journal:  Methods Cell Biol       Date:  1982       Impact factor: 1.441

8.  Microtubular origin of mitotic spindle form birefringence. Demonstration of the applicability of Wiener's equation.

Authors:  H Sato; G W Ellis; S Inoué
Journal:  J Cell Biol       Date:  1975-12       Impact factor: 10.539

9.  Studies on depolarization of light at microscope lens surfaces. II. The simultaneous realization of high resolution and high sensitivity with the polarizing microscope.

Authors:  S INOUE; W L HYDE
Journal:  J Biophys Biochem Cytol       Date:  1957-11-25

10.  Cell-substrate contacts illuminated by total internal reflection fluorescence.

Authors:  D Axelrod
Journal:  J Cell Biol       Date:  1981-04       Impact factor: 10.539

  10 in total
  2 in total

1.  Birefringence of single and bundled microtubules.

Authors:  R Oldenbourg; E D Salmon; P T Tran
Journal:  Biophys J       Date:  1998-01       Impact factor: 4.033

2.  Evaluation of a spectrally resolved scattering microscope.

Authors:  Michael Schmitz; Thomas Rothe; Alwin Kienle
Journal:  Biomed Opt Express       Date:  2011-08-23       Impact factor: 3.732

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.