Literature DB >> 8744018

Fast interleaved echo-planar imaging with navigator: high resolution anatomic and functional images at 4 Tesla.

S G Kim, X Hu, G Adriany, K Uğurbil.   

Abstract

Echo-planar imaging (EPI) is sensitive to magnetic field inhomogeneities, which lead to signal loss and geometric distortions of the image. Magnetic field inhomogeneities induced by susceptibility differences, as encountered in the human body, increase with the magnetic field strength, thus, complicating implementation of high resolution EPI techniques on high magnetic field systems. These problems were overcome by using a fast multishot high resolution EPI method that uses variable flip angles, center-out k-space sampling, and navigator echoes. This approach maximizes signal-to-noise ratio, reduces flow artifacts, and permits correction of intersegment amplitude and phase variations, providing high spatial and temporal resolution. This scheme can be implemented with a single magnetization preparation for contrast that precedes the segments. The utility of this ultrafast segmented EPI technique with navigator is demonstrated for anatomic and functional imaging studies on the human brain at 4 T.

Entities:  

Mesh:

Year:  1996        PMID: 8744018     DOI: 10.1002/mrm.1910350618

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

Review 1.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

Review 2.  The neural basis of the blood-oxygen-level-dependent functional magnetic resonance imaging signal.

Authors:  Nikos K Logothetis
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2002-08-29       Impact factor: 6.237

3.  PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions.

Authors:  Fu-Nien Wang; Teng-Yi Huang; Fa-Hsuan Lin; Tzu-Chao Chuang; Nan-Kuei Chen; Hsiao-Wen Chung; Cheng-Yu Chen; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

4.  Reducing vascular variability of fMRI data across aging populations using a breathholding task.

Authors:  Daniel A Handwerker; Adam Gazzaley; Ben A Inglis; Mark D'Esposito
Journal:  Hum Brain Mapp       Date:  2007-09       Impact factor: 5.038

5.  Improved cortical-layer specificity of vascular space occupancy fMRI with slab inversion relative to spin-echo BOLD at 9.4 T.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2007-12-08       Impact factor: 6.556

6.  The Importance of k-Space Trajectory on Off-Resonance Artifact in Segmented Echo-Planar Imaging.

Authors:  Jacob A Bender; Rizwan Ahmad; Orlando P Simonetti
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2013-03-01       Impact factor: 0.481

7.  Functional activation in motor cortex reflects the direction and the degree of handedness.

Authors:  P Dassonville; X H Zhu; K Uurbil; S G Kim; J Ashe
Journal:  Proc Natl Acad Sci U S A       Date:  1997-12-09       Impact factor: 11.205

8.  High spatial resolution compressed sensing (HSPARSE) functional MRI.

Authors:  Zhongnan Fang; Nguyen Van Le; ManKin Choy; Jin Hyung Lee
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

9.  Cortical correlates of human motion perception biases.

Authors:  Brett Vintch; Justin L Gardner
Journal:  J Neurosci       Date:  2014-02-12       Impact factor: 6.167

10.  Contrast adaptation and representation in human early visual cortex.

Authors:  Justin L Gardner; Pei Sun; R Allen Waggoner; Kenichi Ueno; Keiji Tanaka; Kang Cheng
Journal:  Neuron       Date:  2005-08-18       Impact factor: 17.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.