Literature DB >> 874175

Radionuclide left ventriculography with the slant hole collimator.

J A Parker, R F Uren, A G Jones, D E Maddox, R E Zimmerman, J M Neill, B L Holman.   

Abstract

A 30 degrees slant-hole collimator was used during radionuclide ventriculography of the cardiac blood pool to improve imaging of the heart in both the modified left anterior oblique (MLAO) and right anterior oblique (RAO) views. In the MLAO view, with the holes slanted caudally, good separation between the left atrium and left ventricle was achieved, and the septum was displayed without foreshortening. In the RAO view with the collimator flat against the chest there was better resolution of the cardiac apex. The results of ejection fraction and wall motion analysis in these patients correlated well with contrast ventriculography (r=0.94). Combination of the slant-hole collimator, in vivo red blood cell labeling with stannous pyrophosphate, simultaneous collection of all phases of the cardiac cycle, and cine mode display, provide a practical system for the noninvasive measurement of left ventricular performance parameters.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 874175

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  12 in total

1.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

2.  Clinical validation of fully-automated contour detection for gated radionuclide ventriculography with a slant-hole collimator.

Authors:  M Hosoba; H Wani; M Hiroe; K Kusakabe
Journal:  Eur J Nucl Med       Date:  1986

Review 3.  Cardiac nuclear medicine: an overview.

Authors:  B L Holman
Journal:  Cardiovasc Radiol       Date:  1979-09

4.  Quantitative analysis of left ventricular function from equilibrium gated blood pool scintigrams: an overview of computer methods.

Authors:  J H Reiber
Journal:  Eur J Nucl Med       Date:  1985

5.  Comparison of three semiautomatic methods for determination of left ventricular ejection fraction from gated cardiac blood pool images.

Authors:  J Bingham; R Okada; K McKusick; C Boucher; E Tarolli; N Alpert; W Strauss
Journal:  Eur J Nucl Med       Date:  1985

6.  Dynamic scintigraphy with high temporal resolution. Phase dynamic studies of rapid periodical processes.

Authors:  V Ullmann; L Dubroka; O Kuchar; J Kuba
Journal:  Eur J Nucl Med       Date:  1980

7.  Cardiac studies using red blood cells labeled with Tc-99m in vivo with single intravenous injections--first pass technique, gating and blood pool scanning.

Authors:  S Czaplicki; E Dziuk; W Konieczny; Z Bałtrukiewicz
Journal:  Eur J Nucl Med       Date:  1980

8.  Equilibrium (gated) radionuclide ventriculography.

Authors:  W E Adam; A Tarkowska; F Bitter; M Stauch; H Geffers
Journal:  Cardiovasc Radiol       Date:  1979-09

9.  Effect of long-term cimetidine treatment on left ventricular function in haemodialysis patients with active hyperparathyroidism.

Authors:  K N Lai; R G Fassett; T H Mathew
Journal:  Br J Clin Pharmacol       Date:  1982-05       Impact factor: 4.335

10.  Serial cardiac function tests in myocarditis.

Authors:  C L Miklozek; E M Kingsley; C S Crumpaker; J F Modlin; H D Royal; P C Come; R Mark; W H Abelmann
Journal:  Postgrad Med J       Date:  1986-06       Impact factor: 2.401

View more