Literature DB >> 8741372

Usefulness of thallium-201 single photon emission computed tomography to quantify the malignancy grade of brain tumors.

K Igase1, Y Oka, S Ohta, Y Murakami, Y Kumon, S Sakaki.   

Abstract

Preoperative thallium-201 (201Tl) single photon emission computed tomography (SPECT) was used to evaluate the histological malignancy in 24 patients with brain tumors. A corrected L/E ratio was calculated based on the ratio of thallium uptake in the tumor on early images versus the tumor in the delayed images (L/E ratio) corrected for thallium uptake in the contralateral cerebral hemisphere. The corrected L/E ratio in benign brain tumors was 0.79 +/- 0.23, significantly different to 1.32 +/- 0.25 in high grade astrocytomas (p < 0.01) and 1.19 +/- 0.05 in metastatic brain tumors (p < 0.01), respectively. The corrected L/E ratio in low grade astrocytomas was 0.64 +/- 0.32, significantly lower than that in high grade astrocytomas (p < 0.01) and metastatic brain tumors (p < 0.05). There was one false positive result among 24 patients using a threshold of 1.0 to separate malignant and benign tumors. 201Tl SPECT using the corrected L/E ratio is effective for determining the malignant viability of tumors.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8741372     DOI: 10.2176/nmc.36.434

Source DB:  PubMed          Journal:  Neurol Med Chir (Tokyo)        ISSN: 0470-8105            Impact factor:   1.742


  2 in total

1.  Neuroradiological assessment of newly diagnosed glioblastoma.

Authors:  Srini Mukundan; Chad Holder; Jeffrey J Olson
Journal:  J Neurooncol       Date:  2008-08-20       Impact factor: 4.130

2.  Usefulness of thallium-201 SPECT in the evaluation of tumor natures in intracranial meningiomas.

Authors:  Tetsuji Takeda; Takahiro Nakano; Kenichiroh Asano; Norihito Shimamura; Hiroki Ohkuma
Journal:  Neuroradiology       Date:  2011-01-08       Impact factor: 2.804

  2 in total