Literature DB >> 874109

Estimation of serum gentamicin by quenching fluoroimmunoassay.

E J Shaw, R A Watson, J Landon, D S Smith.   

Abstract

A new type of non-isotopic immunoassay, applied to the determination of serum gentamicin, is reported. The method is based on partial quenching of fluorescence observed when fluorescein-labelled gentamicin is bound by anti-gentamicin serum. The fluorescence intensity of the labelled gentamicin in an unseparated immunoassay incubation mixture therefore serves to indicate the extent of binding, which is related to the amount of competing unlabelled gentamicin present. Precision and accuracy are shown to be similar to those of the best existing methods for gentamicin, while the new assay is more rapid and technically simpler, and avoids the use of expensive radio-chemicals with their attendant health hazard. Assays of patient samples correlate with established bioassay and polarisation fluoroimmunoassay methods.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 874109      PMCID: PMC476462          DOI: 10.1136/jcp.30.6.526

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  12 in total

1.  Serum gentamicin assay: a comparison and assessment of different methods.

Authors:  I Phillips; C Warren; S E Smith
Journal:  J Clin Pathol       Date:  1974-06       Impact factor: 3.411

2.  Rapid gentamicin assay by enzymatic adenylylation.

Authors:  E ten Krooden; J H Darrell
Journal:  J Clin Pathol       Date:  1974-06       Impact factor: 3.411

3.  A rapid chemical assay for gentamicin.

Authors:  D H Smith; B Van Otto; A L Smith
Journal:  N Engl J Med       Date:  1972-03-16       Impact factor: 91.245

4.  One-hour radioimmunoassay of serum drug concentrations, as exemplified by digoxin and gentamicin.

Authors:  L S Berk; J L Lewis; J C Nelson
Journal:  Clin Chem       Date:  1974-09       Impact factor: 8.327

5.  Assay of gentamicin.

Authors:  D S Reeves
Journal:  Lancet       Date:  1972-12-23       Impact factor: 79.321

6.  Simple, rapid method for assay of aminoglycoside antibiotics.

Authors:  P Noone; J R Pattison; D Samson
Journal:  Lancet       Date:  1971-07-03       Impact factor: 79.321

7.  The acetyltransferase enzyme method for the assay of serum gentamicon concentrations and a comparison with other methods.

Authors:  J M Broughall; D S Reeves
Journal:  J Clin Pathol       Date:  1975-02       Impact factor: 3.411

8.  Quality control of serum gentamicin assays--experience of national surveys.

Authors:  D S Reeves; M J Bywater
Journal:  J Antimicrob Chemother       Date:  1975-03       Impact factor: 5.790

9.  Polarisation fluoroimmunoassay of gentamicin.

Authors:  R A Watson; J Landon; E J Shaw; D S Smith
Journal:  Clin Chim Acta       Date:  1976-11-15       Impact factor: 3.786

10.  Radioimmunoassay for measurement of gentamicin in blood.

Authors:  W A Mahon; J Ezer; T W Wilson
Journal:  Antimicrob Agents Chemother       Date:  1973-05       Impact factor: 5.191

View more
  4 in total

1.  UK NEQAS in antibiotic assays.

Authors:  L O White
Journal:  J Clin Pathol       Date:  2000-11       Impact factor: 3.411

2.  Homogeneous immunoassays.

Authors:  R C Boguslaski; T M Li
Journal:  Appl Biochem Biotechnol       Date:  1982-09       Impact factor: 2.926

3.  Rapid, simple enzyme immunoassay for gentamicin.

Authors:  P J Wills; R Wise
Journal:  Antimicrob Agents Chemother       Date:  1979-07       Impact factor: 5.191

4.  Comparison of a simplified liquid chromatographic assay of gentamicin in serum with enzyme immunoassay and bioassay.

Authors:  L Essers
Journal:  Eur J Clin Microbiol       Date:  1982-12       Impact factor: 3.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.