Literature DB >> 8733493

Potential effects of correction of inaccuracies of the mini-Wright peak expiratory flow meter on the use of an asthma self-management plan.

J F Miles1, W Tunnicliffe, R M Cayton, J G Ayres, M R Miller.   

Abstract

BACKGROUND: Patient self-management plans for asthma use peak expiratory flow (PEF) meter readings for decisions on adjusting asthma treatment. PEF meters have been shown to be inaccurate and the effect of this inaccuracy on such treatment plans has been determined.
METHODS: PEF measurements were made by 127 severe asthmatic patients at least twice a day for at least two weeks using a mini-Wright meter. The daily variation from "best" PEF and the within day PEF variability were calculated before and after correction for the meter's known inaccuracy. The effect of this data correction on the number of days when trigger points were reached for changing asthma therapy was then determined.
RESULTS: Continuous PEF readings were available from 114 subjects with a median of 157.5 days of data per subject (range 15-489 days). Correction of the PEF data led to the number of days of satisfactory asthma control being reduced in 72% of subjects with just one subject showing an increase in satisfactory control. Data correction reduced the percentage of total days of satisfactory control from 46% to 36% of days, and increased the days requiring more inhaled steroids from 33% to 36%. The days on which a course of oral corticosteroids was required increased from 16% to 23%.
CONCLUSIONS: The accuracy of PEF meters significantly influences the interpretation of currently used asthma self-management plans. Managing asthma with the corrected PEF data would have increased the amount of treatment received by these patients since the severity of the asthma was underestimated by the raw data.

Entities:  

Mesh:

Year:  1996        PMID: 8733493      PMCID: PMC1090676          DOI: 10.1136/thx.51.4.403

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  15 in total

1.  Factors related to the nocturnal worsening of asthma.

Authors:  R J Martin; L C Cicutto; R D Ballard
Journal:  Am Rev Respir Dis       Date:  1990-01

2.  Longitudinal study of near fatal asthma.

Authors:  R E Ruffin; K M Latimer; D A Schembri
Journal:  Chest       Date:  1991-01       Impact factor: 9.410

3.  Asthma education programs: their role in asthma morbidity and mortality.

Authors:  M C Hindi-Alexander
Journal:  J Allergy Clin Immunol       Date:  1987-09       Impact factor: 10.793

4.  Death from asthma.

Authors:  D Stableforth
Journal:  Thorax       Date:  1983-11       Impact factor: 9.139

5.  Evaluation of peak flow and symptoms only self management plans for control of asthma in general practice.

Authors:  I Charlton; G Charlton; J Broomfield; M A Mullee
Journal:  BMJ       Date:  1990-12-15

6.  A self management plan in the treatment of adult asthma.

Authors:  R Beasley; M Cushley; S T Holgate
Journal:  Thorax       Date:  1989-03       Impact factor: 9.139

7.  Sudden death in asthma.

Authors:  J R Bateman; S W Clarke
Journal:  Thorax       Date:  1979-02       Impact factor: 9.139

8.  Accuracy of mini peak flow meters in indicating changes in lung function in children with asthma.

Authors:  P D Sly; P Cahill; K Willet; P Burton
Journal:  BMJ       Date:  1994-02-26

9.  Near-fatal asthma: clinical and physiologic features, perception of bronchoconstriction, and psychologic profile.

Authors:  L P Boulet; F Deschesnes; H Turcotte; F Gignac
Journal:  J Allergy Clin Immunol       Date:  1991-12       Impact factor: 10.793

10.  Asthma: analysis of sudden deaths and ventilatory arrests in hospital.

Authors:  M R Hetzel; T J Clark; M A Branthwaite
Journal:  Br Med J       Date:  1977-03-26
View more
  3 in total

1.  Is home monitoring of lung function worthwhile for children with asthma?

Authors:  P D Sly; F Flack
Journal:  West J Med       Date:  2001-11

2.  Inadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device.

Authors:  M R Miller; P R Atkins; O F Pedersen
Journal:  Thorax       Date:  2003-05       Impact factor: 9.139

3.  Effects of equipment and technique on peak flow measurements.

Authors:  Thomas Bongers; B Ronan O'Driscoll
Journal:  BMC Pulm Med       Date:  2006-06-20       Impact factor: 3.317

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.