Cardiac arrest in an extremely low birth weight infant: complication of percutaneous central venous catheter hyperalimentation.

P Sasidharan1, D Billman, R Heimler, L Nelin.   

Abstract

We report a case of unexpected sudden cardiac arrest in an extremely low birth weight infant on the eighth day after a percutaneous silicone rubber central venous catheter was inserted for parenteral nutrition. The unique pathologic condition of infiltration of the myocardium with probably intralipid and degeneration of myocardial fibers over the right atrium and part of the right ventricle has not been reported in the past. There was no pericardial effusion. A brief review of the complications of central venous catheters is given.

Entities:  

Mesh:

Year:  1996        PMID: 8732560

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  2 in total

1.  Central venous lines in neonates: a study of 2186 catheters.

Authors:  D W Cartwright
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-11       Impact factor: 5.747

Review 2.  Malfunctioning central venous catheters in children: a diagnostic approach.

Authors:  Alex Barnacle; Owen J Arthurs; Derek Roebuck; Melanie P Hiorns
Journal:  Pediatr Radiol       Date:  2007-10-12
  2 in total