Literature DB >> 8730023

Bronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients.

R Dhand1, M J Tobin.   

Abstract

Metered-dose inhalers (MDIs) provide several advantages over nebulizers, including ease of administration, decreased cost, reliability of dosing, and freedom from contamination. However, this method of aerosol delivery has been considered ineffective in mechanically-ventilated patients because most of the aerosol deposits in the endotracheal tube and ventilator circuit. A smaller amount of aerosol from a MDI is deposited in the lower respiratory tract of mechanically-ventilated patients than in ambulatory patients, although recent studies show that a significant bronchodilator effect can still be achieved. When employed optimally, significant bronchodilation occurs with as little as 4 puffs of a sympathomimetic aerosol. Multiple factors influence the efficacy of MDIs in mechanically-ventilated patients. The method of connecting the MDI canister to the ventilator circuit has a marked effect on aerosol delivery, and other factors include the timing of MDI actuation, ventilator mode, tidal volume, circuit humidity, and duty cycle. With a proper technique of administration, a MDI serves as an effective, convenient, and safe method for delivering bronchodilator aerosols in mechanically-ventilated patients.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8730023     DOI: 10.1183/09031936.96.09030585

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  10 in total

Review 1.  Mechanical ventilation of the patient with severe chronic obstructive pulmonary disease.

Authors:  M T Gladwin; D J Pierson
Journal:  Intensive Care Med       Date:  1998-09       Impact factor: 17.440

Review 2.  Nebuliser therapy in the intensive care unit.

Authors:  M J O'Doherty; S H Thomas
Journal:  Thorax       Date:  1997-04       Impact factor: 9.139

Review 3.  Administration of dry powders during respiratory supports.

Authors:  Wei-Ren Ke; Rachel Yoon Kyung Chang; Philip Chi Lip Kwok; Patricia Tang; Lan Chen; Donghao Chen; Hak-Kim Chan
Journal:  Ann Transl Med       Date:  2021-04

4.  The utilization of aerosol therapy in mechanical ventilation patients: a prospective multicenter observational cohort study and a review of the current evidence.

Authors:  Shan Lyu; Jie Li; Limin Yang; Xiaoliang Du; Xiaoyi Liu; Libo Chuan; Guoqiang Jing; Zhenyan Wang; Weiwei Shu; Chunjuan Ye; Qionglan Dong; Jun Duan; James B Fink; Zhancheng Gao; Zongan Liang
Journal:  Ann Transl Med       Date:  2020-09

5.  Aerosol therapy during mechanical ventilation: an international survey.

Authors:  Stephan Ehrmann; Ferran Roche-Campo; Giuseppe Francesco Sferrazza Papa; Daniel Isabey; Laurent Brochard; Gabriela Apiou-Sbirlea
Journal:  Intensive Care Med       Date:  2013-03-23       Impact factor: 17.440

6.  In vitro evaluation of aerosol bronchodilator delivery during mechanical ventilation: pressure-control vs. volume control ventilation.

Authors:  Dean R Hess; Christine Dillman; Robert M Kacmarek
Journal:  Intensive Care Med       Date:  2003-05-15       Impact factor: 17.440

Review 7.  Metered dose inhalers versus nebulizers for aerosol bronchodilator delivery for adult patients receiving mechanical ventilation in critical care units.

Authors:  Agi Holland; Fiona Smith; Kay Penny; Gill McCrossan; Linda Veitch; Caroline Nicholson
Journal:  Cochrane Database Syst Rev       Date:  2013-06-06

Review 8.  Bronchodilator delivery with metered-dose inhaler during mechanical ventilation.

Authors:  D Georgopoulos; E Mouloudi; E Kondili; M Klimathianaki
Journal:  Crit Care       Date:  2000-07-11       Impact factor: 9.097

Review 9.  Fundamentals of aerosol therapy in critical care.

Authors:  Jayesh Dhanani; John F Fraser; Hak-Kim Chan; Jordi Rello; Jeremy Cohen; Jason A Roberts
Journal:  Crit Care       Date:  2016-10-07       Impact factor: 9.097

10.  Effect of Tiotropium Soft Mist Inhalers on Dynamic Changes in Lung Mechanics of Patients with Chronic Obstructive Pulmonary Disease Receiving Mechanical Ventilation: A Prospective Pilot Study.

Authors:  Pin-Kuei Fu; Yu-Feng Wei; Chau-Chyun Sheu; Chen-Yu Wang; Chi-Kuei Hsu; Chia-Min Chen; Wei-Chih Chen; Kuang-Yao Yang
Journal:  Pharmaceutics       Date:  2020-12-31       Impact factor: 6.321