Literature DB >> 8729474

Effects of two kinds of underwear on thermophysiological responses and clothing microclimate during 30 min walking and 60 min recovery in the cold.

M Ha1, H Tokura, Y Tanaka, I Holmér.   

Abstract

Thermophysiological responses and clothing microclimate under the influences of different underwear materials were compared during walking and recovery in the cold. Two kinds of underwear were used: two layers of cotton underwear with two-piece long-sleeved shirt and long-legged trousers (C), two layers of polypropylene underwear with two-piece long-sleeved shirt and long-legged trousers (P). In addition, the subject put on a two-piece ski suit of 100% polyester including 100% polyester padding. Seven adult females served as subjects in this study. The test was done in a climatic chamber at an ambient air temperature of 2 degrees C, a relative humidity of 65% and an air velocity of 0.14 m.s-1. The subject walked on a motor-driven treadmill with a 6 km/h speed for 30 min followed by 60 min recovery. Rectal temperature, skin temperatures, clothing microclimate (temperature, humidity), metabolic heat production and heart rate were measured. Furthermore, subjective ratings on thermal sensation, sweating/shivering sensation, clothing wettedness sensation and skin wettedness sensation for whole body were asked. The major findings are summarized as follows: 1) Mean skin temperature was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 2) The absolute humidity of innermost layer and outermost layer were not significantly different during walking, but it was significantly higher in P than in C during the recovery. 3) Clothing microclimate temperature of innermost was not significantly different during the first half of walking, but it was significantly higher in C than in P during the second half of walking and significantly lower in C than in P during the recovery. Clothing microclimate temperature of outermost was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 4) Metabolic heat production for the last 10 min during recovery tended to be higher in P. 5) The degree of skin wettedness sensation and clothing wettedness sensation for whole body was significantly higher in P during walking and recovery. Thus, it was concluded that two kinds of underwear with different properties to moisture could influence, not only clothing microclimate, but also physiological parameters like skin temperatures and metabolic heat production in the cold differently.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8729474     DOI: 10.2114/jpa.15.33

Source DB:  PubMed          Journal:  Appl Human Sci        ISSN: 1341-3473


  9 in total

1.  The influence of interval versus continuous exercise on thermoregulation, torso hemodynamics, and finger dexterity in the cold.

Authors:  Matthew D Muller; Edward J Ryan; David M Bellar; Chul-Ho Kim; Robert P Blankfield; Sarah M Muller; Ellen L Glickman
Journal:  Eur J Appl Physiol       Date:  2010-03-13       Impact factor: 3.078

2.  Effects of wind and rain on thermal responses of humans in a mildly cold environment.

Authors:  Motoi Yamane; Yukio Oida; Norikazu Ohnishi; Takaaki Matsumoto; Kaoru Kitagawa
Journal:  Eur J Appl Physiol       Date:  2010-02-05       Impact factor: 3.078

3.  Two strategies for response to 14 °C cold-water immersion: is there a difference in the response of motor, cognitive, immune and stress markers?

Authors:  Marius Brazaitis; Nerijus Eimantas; Laura Daniuseviciute; Dalia Mickeviciene; Rasa Steponaviciute; Albertas Skurvydas
Journal:  PLoS One       Date:  2014-10-02       Impact factor: 3.240

4.  Physiological and Psychological Responses during Exercise and Recovery in a Cold Environment Is Gender-Related Rather Than Fabric-Related.

Authors:  Margarita Cernych; Neringa Baranauskiene; Nerijus Eimantas; Sigitas Kamandulis; Laura Daniuseviciute; Marius Brazaitis
Journal:  Front Psychol       Date:  2017-08-07

5.  Heat dissipating upper body compression garment: Thermoregulatory, cardiovascular, and perceptual responses.

Authors:  Iker Leoz-Abaurrea; Nicholas Tam; Roberto Aguado-Jiménez
Journal:  J Sport Health Sci       Date:  2016-01-11       Impact factor: 7.179

6.  Clothing insulation and temperature, layer and mass of clothing under comfortable environmental conditions.

Authors:  JuYoun Kwon; Jeongwha Choi
Journal:  J Physiol Anthropol       Date:  2013-07-01       Impact factor: 2.867

7.  Time course of physiological and psychological responses in humans during a 20-day severe-cold-acclimation programme.

Authors:  Marius Brazaitis; Nerijus Eimantas; Laura Daniuseviciute; Neringa Baranauskiene; Erika Skrodeniene; Albertas Skurvydas
Journal:  PLoS One       Date:  2014-04-10       Impact factor: 3.240

8.  Effect of lower body compression garments on hemodynamics in response to running session.

Authors:  Tomas Venckūnas; Eugenijus Trinkūnas; Sigitas Kamandulis; Jonas Poderys; Albinas Grūnovas; Marius Brazaitis
Journal:  ScientificWorldJournal       Date:  2014-08-18

9.  Prolonged Sitting Interrupted by 6-Min of High-Intensity Exercise: Circulatory, Metabolic, Hormonal, Thermal, Cognitive, and Perceptual Responses.

Authors:  Billy Sperlich; Ine De Clerck; Christoph Zinner; Hans-Christer Holmberg; Birgit Wallmann-Sperlich
Journal:  Front Physiol       Date:  2018-10-16       Impact factor: 4.566

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.