Monitoring of pulmonary fluid volume and stroke volume by impedance cardiography in patients on hemodialysis.

G Keller, A Blumberg.   

Abstract

Changes of intrathoracic fludi volume during maintenance therapy with hemodialysis were studied in ten patients with the aid of impedance cardiography. It was found that there was a statistically significant correlation between the decrease in body weight and the increase in basic thoracic impedance in the individual patients, but the values differed considerably from one patient to another. Therefore, comparison of sequential measurements is feasible only in one and the same patient. Out of 16 patients with overhydration undergoing dialysis, the stroke volume could not be determined by impedance cardiographic studies in eight, owing to the abnormal morphology of the dZ/dt curve. Moreover, because the basic thoracic impedance was not constant during treatment, the calculated changes in stroke volume did not appear to be reliable. This has to be taken into account when repeated measurements are made under clinical conditions. In some of the patients, the dZ/dt curve displayed interesting anomalies, probably resulting from hemodynamic alterations. The diagnostic meaning of these features is not yet known.

Entities:  

Mesh:

Year:  1977        PMID: 872655     DOI: 10.1378/chest.72.1.56

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  5 in total

1.  Equipment using an impedance technique for automatic recording of fluid-volume changes during haemodialysis.

Authors:  B Tedner
Journal:  Med Biol Eng Comput       Date:  1983-05       Impact factor: 2.602

2.  Differential impedance plethysmography for measuring thoracic impedances.

Authors:  J H Meijer; J P Reulen; P L Oe; W Allon; L G Thijs; H Schneider
Journal:  Med Biol Eng Comput       Date:  1982-03       Impact factor: 2.602

3.  Considerations on impedance cardiography.

Authors:  P Casthély; S Ramanathan; J Chalon
Journal:  Can Anaesth Soc J       Date:  1980-09

4.  Transthoracic electrical impedance during extracorporeal hemodialysis in acute respiratory failure ("Shocked Lung syndrome").

Authors:  H P Schuster; C J Schuster; H J Gilfrich; P Schölmerich
Journal:  Intensive Care Med       Date:  1980-05       Impact factor: 17.440

5.  Transthoracic electrical impedance as an index of extracellular fluid volume in man.

Authors:  J C Roos; H A Koomans; P Boer; E J Dorhout Mees
Journal:  Intensive Care Med       Date:  1985       Impact factor: 17.440

  5 in total