Identification of peak stresses in cardiac prostheses. A comparison of two-dimensional versus three-dimensional principal stress analyses.

A A Fontaine1, J T Ellis, T M Healy, J Hopmeyer, A P Yoganathan.   

Abstract

This study assessed the accuracy of using a two-dimensional principal stress analysis compared to a three-dimensional analysis in estimating peak turbulent stresses in complex three-dimensional flows associated with cardiac prostheses. Three-component, coincident laser Doppler anemometer measurements were obtained in steady flow downstream of three prosthetic valves: a St. Jude bileaflet, Bjork-Shiley monostrut tilting disc, and Starr-Edwards ball and cage. Two-dimensional and three-dimensional principal stress analyses were performed to identify local peak stresses. Valves with locally two-dimensional flows exhibited a 10-15% underestimation of the largest measured normal stresses compared to the three-dimensional principal stresses. In nearly all flows, measured shear stresses underestimated peak principal shear stresses by 10-100%. Differences between the two-dimensional and three-dimensional principal stress analysis were less than 10% in locally two-dimensional flows. In three-dimensional flows, the two-dimensional principal stresses typically underestimated three-dimensional values by nearly 20%. However, the agreement of the two-dimensional principal stress with the three-dimensional principal stresses was dependent upon the two velocity-components used in the two-dimensional analysis, and was observed to vary across the valve flow field because of flow structure variation. The use of a two-dimensional principal stress analysis with two-component velocity data obtained from measurements misaligned with the plane of maximum mean flow shear can underpredict maximum shear stresses by as much as 100%.

Mesh:

Year:  1996        PMID: 8725681     DOI: 10.1097/00002480-199605000-00007

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  Measurements of steady flow through a bileaflet mechanical heart valve using stereoscopic PIV.

Authors:  Chris Hutchison; Pierre Sullivan; C Ross Ethier
Journal:  Med Biol Eng Comput       Date:  2010-11-16       Impact factor: 2.602

2.  Adverse Hemodynamic Conditions Associated with Mechanical Heart Valve Leaflet Immobility.

Authors:  Fardin Khalili; Peshala P T Gamage; Richard H Sandler; Hansen A Mansy
Journal:  Bioengineering (Basel)       Date:  2018-09-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.