Literature DB >> 8725549

Long-term clinical experience with continuous ambulatory peritoneal dialysis: access-related problems.

Y C Paquay1, J A Jansen, R J Goris, A J Hoitsma.   

Abstract

Patients with end-stage renal failure can be treated with peritoneal dialysis, which is based on the capacity of the peritoneum to exchange fluid and metabolic products. To achieve this, dialysis fluid has to be instilled in the abdominal cavity through a permanent percutaneous access device. Apart from the advantages of peritoneal dialysis, severe problems are related to the access device. In this study, catheter-related morbidity and mortality are described, as found in the patient population from the University Hospital, Nijmegen, The Netherlands. The overall rates of exit-site infections and peritonitis are respectively 0.80 and 1.36 infection episodes per patient-year. Furthermore, it appeared that exit-site infections and peritonitis are the main reasons for discontinuation of dialysis and removal of the catheter. A correlation between the occurrence of peritonitis and exit-site infections was found. Also, the efficacy of the antibiotic treatment necessary to control these infectious complications is described. It is concluded that the design and the materials used to manufacture the currently used access device are the main reason for the existing morbidity in peritoneal dialysis. Therefore, more efforts should be undertaken to improve the access device, in which the design and the material used are critically considered.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8725549     DOI: 10.3109/08941939609012462

Source DB:  PubMed          Journal:  J Invest Surg        ISSN: 0894-1939            Impact factor:   2.533


  4 in total

1.  Evaluation of the tissue reaction to a percutaneous access device using titanium fibre mesh anchorage in goats.

Authors:  M Gerritsen; Y G Paquay; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  1998-09       Impact factor: 3.896

Review 2.  A qualitative systematic review of the literature supporting a causal relationship between exit-site infection and subsequent peritonitis in patients with end-stage renal disease treated with peritoneal dialysis.

Authors:  Anouk T N van Diepen; Sarbjit V Jassal
Journal:  Perit Dial Int       Date:  2013 Nov-Dec       Impact factor: 1.756

3.  The association between exit site infection and subsequent peritonitis among peritoneal dialysis patients.

Authors:  Anouk T N van Diepen; George A Tomlinson; Sarbjit V Jassal
Journal:  Clin J Am Soc Nephrol       Date:  2012-06-28       Impact factor: 8.237

4.  The influence of bone formation on anchoring percutaneous devices with titanium fibre mesh flanges.

Authors:  M M Shalabi; X F Walboomers; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  2004-07       Impact factor: 3.896

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.