Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: comparison of T1-weighted spin-echo and 3D gradient-echo sequences.

D Li1, E M Haacke, R W Tarr, R Venkatesan, W Lin, P Wielopolski.   

Abstract

Short TR, short TE, high resolution, 3D gradient-recalled echo (GRE) imaging was evaluated for lesion detection in the brain. High resolution 3D GRE data acquisition was used to reduce partial volume effects and flow artifacts, to better visualize smaller structures, to minimize signal losses caused by field inhomogeneities, and to allow better image reformatting. Spin-echo (SE) and 3D GRE approaches were compared for lesion detection after the administration of an MR contrast agent, gadopentetate dimeglumine. Preliminary clinical studies demonstrated that the signal-to-noise ratio (SNR) in each slice of the GRE scan was worse than that of the SE scan because of the much thicker slices acquired with the SE technique. However, by averaging two adjacent 3D slices, the SNR of the two methods was essentially equivalent. In the averaged GRE slices, large lesions were seen just as well as in the SE images. More importantly, small lesions were better visualized in the thin 3D GRE images than in the thick SE images for the lesions studied in this work and the protocols used. These observations were confirmed by theoretical simulations.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8724406     DOI: 10.1002/jmri.1880060302

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T.

Authors:  Richard Keith Downs; Mariah Haider Bashir; Chin Kau Ng; Jens Olaf Heidenreich
Journal:  Quant Imaging Med Surg       Date:  2013-06

2.  Cerebral staging of lung cancer: is one single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence sufficient?

Authors:  Mickaël Ohana; Mi-Young Jeung; Gauthier Bazille; Catherine Roy
Journal:  Neuroradiology       Date:  2014-05-15       Impact factor: 2.804

3.  Three-dimensional T1-weighted gradient echo is a suitable alternative to two-dimensional T1-weighted spin echo for imaging the canine brain.

Authors:  Kathryn L Fleming; Thomas W Maddox; Christopher M R Warren-Smith
Journal:  Vet Radiol Ultrasound       Date:  2019-05-30       Impact factor: 1.363

4.  Three-dimensional Gradient-echo is Effective in Suppressing Radiofrequency Shielding by a Titanium Mesh.

Authors:  Yasuo Takatsu; Rei Yoshida; Kenichiro Yamamura; Yuya Yamatani; Tsuyoshi Ueyama; Tetsuya Kimura; Yuriko Nohara; Tomohiro Sahara; Kengo Nishiyama; Tosiaki Miyati
Journal:  Magn Reson Med Sci       Date:  2020-06-26       Impact factor: 2.471

5.  Ankle MRI for anterolateral soft tissue impingement: increased accuracy with the use of contrast-enhanced fat-suppressed 3D-FSPGR MRI.

Authors:  Hye Jung Choo; Jin-Suck Suh; Sung-Jun Kim; Yong-Min Huh; Myung In Kim; Jin-Woo Lee
Journal:  Korean J Radiol       Date:  2008 Sep-Oct       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.