Literature DB >> 8722826

Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI.

N Alperin1, E M Vikingstad, B Gomez-Anson, D N Levin.   

Abstract

Brain and cerebrospinal fluid (CSF) movements are influenced by the anatomy and mechanical properties of intracranial tissues, as well as by the waveforms of driving vascular pulsations. The authors analyze these movements so that the purely hemodynamic factors are removed and the underlying mechanical couplings between brain, CSF, and the vasculature are characterized in global fashion. These measurements were used to calculate a set of impulse response functions or modulation transfer functions, characterizing global aspects of the vasculature's mechanical coupling to the intracranial tissues, the cervical CSF, and the cervical spinal cord. These functions showed that a sudden influx of blood into the head was rapidly accommodated by some type of intracranial reserve or capacity. After this initial response, an equal volume of CSF was driven through the foramen magnum over the next 200-300 ms as the intracranial reserve relaxed to its base-line state.

Mesh:

Year:  1996        PMID: 8722826     DOI: 10.1002/mrm.1910350516

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Phase-contrast MR imaging of the cervical CSF and spinal cord: volumetric motion analysis in patients with Chiari I malformation.

Authors:  E Hofmann; M Warmuth-Metz; M Bendszus; L Solymosi
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

Review 2.  Intrathecal therapy for chronic pain: current trends and future needs.

Authors:  Salim M Hayek; Michael C Hanes
Journal:  Curr Pain Headache Rep       Date:  2014-01

3.  Tracking brain motion during the cardiac cycle using spiral cine-DENSE MRI.

Authors:  Xiaodong Zhong; Craig H Meyer; David J Schlesinger; Jason P Sheehan; Frederick H Epstein; James M Larner; Stanley H Benedict; Paul W Read; Ke Sheng; Jing Cai
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

4.  Revealing sub-voxel motions of brain tissue using phase-based amplified MRI (aMRI).

Authors:  Itamar Terem; Wendy W Ni; Maged Goubran; Mahdi Salmani Rahimi; Greg Zaharchuk; Kristen W Yeom; Michael E Moseley; Mehmet Kurt; Samantha J Holdsworth
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

5.  Influence of the compliance of the neck arteries and veins on the measurement of intracranial volume change by phase-contrast MRI.

Authors:  Rong-Wen Tain; Birgit Ertl-Wagner; Noam Alperin
Journal:  J Magn Reson Imaging       Date:  2009-10       Impact factor: 4.813

6.  Comparative Study of Outcomes between Shunting after Cranioplasty and in Cranioplasty after Shunting in Large Concave Flaccid Cranial Defect with Hydrocephalus.

Authors:  Chang Hyun Oh; Chong Oon Park; Dong Keun Hyun; Hyung Chun Park; Seung Hwan Yoon
Journal:  J Korean Neurosurg Soc       Date:  2008-10-30

7.  Improved in vivo diffusion tensor imaging of human cervical spinal cord.

Authors:  Junqian Xu; Joshua S Shimony; Eric C Klawiter; Abraham Z Snyder; Kathryn Trinkaus; Robert T Naismith; Tammie L S Benzinger; Anne H Cross; Sheng-Kwei Song
Journal:  Neuroimage       Date:  2012-11-21       Impact factor: 6.556

8.  3D amplified MRI (aMRI).

Authors:  Itamar Terem; Leo Dang; Allen Champagne; Javid Abderezaei; Aymeric Pionteck; Zainab Almadan; Anna-Maria Lydon; Mehmet Kurt; Miriam Scadeng; Samantha J Holdsworth
Journal:  Magn Reson Med       Date:  2021-05-05       Impact factor: 4.668

9.  CSF flow quantification of the cerebral aqueduct in normal volunteers using phase contrast cine MR imaging.

Authors:  Jeong Hyun Lee; Ho Kyu Lee; Jae Kyun Kim; Hyun Jeong Kim; Ji Kang Park; Choong Gon Choi
Journal:  Korean J Radiol       Date:  2004 Apr-Jun       Impact factor: 3.500

10.  Cerebral Blood and CSF Flow Patterns in Patients Diagnosed for Cerebral Venous Thrombosis - An Observational Study.

Authors:  Souraya Elsankari; Marek Czosnyka; Pierre Lehmann; Marc-Etienne Meyer; Hervé Deramond; Olivier Balédent
Journal:  J Clin Imaging Sci       Date:  2012-07-28
View more