Single-shot, B1-insensitive slice selection with a gradient-modulated adiabatic pulse, BISS-8.

R A de Graaf1, K Nicolay, M Garwood.   

Abstract

An adiabatic pulse has been developed to accomplish uniform slice-selective excitation with a spatially inhomogeneous B1. This new pulse can generate a uniform, arbitrary flip angle that is determined by four adjustable phase shifts in the pulse. Self-refocused slice selection is achieved by modulating a B(O) gradient in concert with the pulse frequency (or phase) modulation. B1-compensated, self-refocused slice selection is demonstrated in computer simulations and phantom experiments using a surface transmitter/receiver coil. This adiabatic pulse can provide optimal performance in multislice MRI and localized spectroscopy when transmitting with an inhomogeneous B1.

Entities:  

Mesh:

Year:  1996        PMID: 8722815     DOI: 10.1002/mrm.1910350505

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Reduction of CSF artifacts on FLAIR images by using adiabatic inversion pulses.

Authors:  J V Hajnal; A Oatridge; A H Herlihy; G M Bydder
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

2.  Slice-selective tunable-flip adiabatic low peak-power excitation pulse.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

3.  Brain metabolites B1-corrected proton T1 mapping in the rhesus macaque at 3 T.

Authors:  Songtao Liu; Roman Fleysher; Lazar Fleysher; Chan-Gyu Joo; Eva-Maria Ratai; R Gilberto González; Oded Gonen
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

4.  Designing adiabatic radio frequency pulses using the Shinnar-Le Roux algorithm.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

5.  Slice-selective excitation with B₁⁺-insensitive composite pulses.

Authors:  Jay Moore; Marcin Jankiewicz; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2011-11-18       Impact factor: 2.229

6.  Spin-echo MRI using pi/2 and pi hyperbolic secant pulses.

Authors:  Jang-Yeon Park; Michael Garwood
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

7.  Improved slice-selective adiabatic excitation.

Authors:  Priti Balchandani; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2013-02-11       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.