Literature DB >> 8717169

[Alloplastic augmented femoral reinserted anterior cruciate liganent. Value of 2 channel augmentation for postoperative rehabilitation].

H Seitz1, B Wielke, I Schlenz, W Pichl, V Vecsei.   

Abstract

The rupture of the anterior cruciate ligament (ACL) near its femoral origin is a common injury of the knee and can lead to lesions of the meniscus due to instability and to early gonarthrosis. One procedure applied in current orthopaedic practice to prevent such impairment of knee joint function is ACL repair reinforced with a synthetic intraarticular ligament. In this study we used twelve knees of cadavers and after sectioning the ACL in each repaired it according the Marshall technique with USP 1 PDS II sutures. We augmented the repair in each case with a 3-mm PET (Trevira hochfest) band inserted by the through-the-condyle (TTC) procedure and attached without preload to the femoral and tibial condyle with a 4-mm staple. We then measured the length of the ACL, the length of the Marshall sutures-ACL complex, the partial lengths, and the deviation angles and adherence-friction force of the 3-mm PET augmentation device, and applied the law of Hooke to calculate the load-sharing between the USP 1 PDS II sutures-ACL complex and the 3-mm PET band and between the ACL and the 3-mm PET band, respectively. We also evaluated the load on the femoral and the tibial fixation of the augmentation device. The results showed that the 3-mm PET band took over 60% of an externally applied load on the knee during the hypothetic period of ACL healing and 27% of the force acting on the knee thereafter. It was calculated that a maximum of 75% of the load taken over by the augmentation device was at the tibial staple and only up to 45% of the force at the femoral one. With due consideration for the requirement for absolute protection ("stress shielding") of the healing ACL but also for the aim of early postoperative accelerated functional rehabilitation without casts, splints or other restrictions of joint movement, we believe that a pretensioned 3-mm PET band is the best choice, since augmentation without preload cannot fulfil these requirements.

Entities:  

Mesh:

Year:  1996        PMID: 8717169     DOI: 10.1007/BF00184249

Source DB:  PubMed          Journal:  Langenbecks Arch Chir        ISSN: 0023-8236


  21 in total

1.  Augmented repair and early mobilization of acute anterior cruciate ligament injuries.

Authors:  H H Paessler; J Deneke; L E Dahners
Journal:  Am J Sports Med       Date:  1992 Nov-Dec       Impact factor: 6.202

2.  [Reconstruction of the proximal insertion of the anterior cruciate ligament. Studies on the accuracy of a non-instrumental method].

Authors:  M Bernard; P Hertel; E Lais; F Gomez
Journal:  Unfallchirurg       Date:  1990-12       Impact factor: 1.000

3.  The anterior cruciate ligament: a technique of repair and reconstruction.

Authors:  J L Marshall; R F Warren; T L Wickiewicz; B Reider
Journal:  Clin Orthop Relat Res       Date:  1979-09       Impact factor: 4.176

Review 4.  The biochemical and histological effects of artificial ligament wear particles: in vitro and in vivo studies.

Authors:  E J Olson; J D Kang; F H Fu; H I Georgescu; G C Mason; C H Evans
Journal:  Am J Sports Med       Date:  1988 Nov-Dec       Impact factor: 6.202

5.  Direct in vitro measurement of forces in the cruciate ligaments. Part I: The effect of multiplane loading in the intact knee.

Authors:  D C Wascher; K L Markolf; M S Shapiro; G A Finerman
Journal:  J Bone Joint Surg Am       Date:  1993-03       Impact factor: 5.284

6.  Relationship between changes in length and force in in vitro reconstructed anterior cruciate ligament.

Authors:  T Muneta; H Yamamoto; H Sakai; T Ishibashi; K Furuya
Journal:  Am J Sports Med       Date:  1993 Mar-Apr       Impact factor: 6.202

7.  Effect of surgical timing on recovery and associated injuries after anterior cruciate ligament reconstruction.

Authors:  S A Wasilewski; D J Covall; S Cohen
Journal:  Am J Sports Med       Date:  1993 May-Jun       Impact factor: 6.202

8.  [Tension characteristics of transplants replacing the anterior cruciate ligament, together with a contribution to the criticism of the "over-the-top" technic].

Authors:  J Hassenpflug; W Blauth; D Rose
Journal:  Unfallchirurg       Date:  1985-04       Impact factor: 1.000

9.  [Suture protection of acute ruptured anterior cruciate ligament by the Pet-band (Trevira extra strong). Indications, technique results of a five-year study].

Authors:  R Letsch; K M Stürmer; H J Kock; K P Schmit-Neuerburg
Journal:  Unfallchirurg       Date:  1993-10       Impact factor: 1.000

10.  Materials design analysis of the prosthetic anterior cruciate ligament.

Authors:  E H Chen; J Black
Journal:  J Biomed Mater Res       Date:  1980-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.