Literature DB >> 8713730

Changes in thoracic dimensions induced by breathing movements in fetal sheep.

R Harding1, G C Liggins.   

Abstract

The dimensions of the three major axes of the thorax (longitudinal, transverse and antero-posterior) were monitored in utero from the ultrasonic transit-time between pairs of piezo-electric transducers chronically implanted at opposite sides of the thorax in five fetal sheep at 119-122 days of gestation; tracheal and vascular catheters and diaphragmatic EMG electrodes were also implanted. To measure thoracic length, ultrasound transducers were implanted on the diaphragm and over the upper sternum and manubrium sterni. A pair was implanted on opposite sides of the chest to measure thoracic width, and another pair was implanted over the lower thoracic spine and lower sternum (antero-posterior dimension). The width of the thorax either decreased (mean 0.6 +/- 0.2 mm) or increased (mean 0.7 +/- 0.1 mm) during fetal breathing movements (FBM). The depth of the thorax (antero-posterior dimension) usually decreased (mean 0.9 +/- 0.1 mm) during FBM. The distance between the upper sternum and the diaphragm decreased by 1.0 +/- 0.1 mm (left side) and 1.6 +/- 0.3 mm (right side) during inspiratory efforts. The distance between the upper thorax and a fixed point on the lower thoracic spine decreased by a similar amount. Overall, fetal thoracic dimensions changed by 1-3%. The largest changes measured, and the most surprising, were reductions, rather than increases, in the separation between the dome of the diaphragm and the upper thorax; this suggests that, during inspiratory efforts, the upper thorax moves caudally by a greater distance than the diaphragm. FBM induce complex and variable changes in thoracic dimensions; these are likely to induce small alterations in the shape of the lungs that may act as a stimulus to lung growth.

Entities:  

Mesh:

Year:  1996        PMID: 8713730     DOI: 10.1071/rd9960117

Source DB:  PubMed          Journal:  Reprod Fertil Dev        ISSN: 1031-3613            Impact factor:   2.311


  5 in total

1.  An experimental system to study mechanotransduction in fetal lung cells.

Authors:  Yulian Wang; Zheping Huang; Pritha S Nayak; Juan Sanchez-Esteban
Journal:  J Vis Exp       Date:  2012-02-16       Impact factor: 1.355

2.  Diffusion-weighted MR imaging of the normal fetal lung.

Authors:  Csilla Balassy; Gregor Kasprian; Peter C Brugger; Bence Csapo; Michael Weber; Marcus Hörmann; Alexander Bankier; Roland Bammer; Christian J Herold; Daniela Prayer
Journal:  Eur Radiol       Date:  2007-10-09       Impact factor: 5.315

3.  The Rho pathway mediates transition to an alveolar type I cell phenotype during static stretch of alveolar type II cells.

Authors:  Cherie D Foster; Linda S Varghese; Linda W Gonzales; Susan S Margulies; Susan H Guttentag
Journal:  Pediatr Res       Date:  2010-06       Impact factor: 3.756

4.  Mechanical stretch promotes fetal type II epithelial cell differentiation via shedding of HB-EGF and TGF-alpha.

Authors:  Yulian Wang; Benjamin S Maciejewski; Dariana Soto-Reyes; Hyeon-Soo Lee; David Warburton; Juan Sanchez-Esteban
Journal:  J Physiol       Date:  2009-02-23       Impact factor: 5.182

Review 5.  Mechanical forces in fetal lung development: opportunities for translational research.

Authors:  Juan Sanchez-Esteban
Journal:  Front Pediatr       Date:  2013-12-25       Impact factor: 3.418

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.