Literature DB >> 8710707

Evaluation of factors affecting the accuracy of impressions using quantitative surface analysis.

I K Lee1, R DeLong, M R Pintado, R Malik.   

Abstract

Impression material goes from a plastic to an elastic state during setting. Movement of the impression and excessive seating pressure during this transition can cause distortion in the impressions. The purpose of this study is to determine if the impression distortion is related to movement during setting or to distortion of the putty phase in the two-step impressioning technique. A master model of a maxillary quadrant of teeth was impressed using four different procedures: 1) one-step technique without movement (1S-NM); 2) one-step technique with movement (1S-M); 3) two-step technique without movement (2S-NM); and 4) two-step technique with movement (2S-M). An artificial oral environment and surface analysis technique of the Minnesota Dental Research Center for Biomaterials and Biomechanics were used to produce the impressions and measure their accuracy. A digitized image of the first premolar of the master model was aligned with a digitized image of the first premolar of each epoxy model using AnSur. The root mean squared difference (RMS) between the aligned images is a measure of the distortion. The corresponding RMS values for the different methods were: 1S-NM = 23.7 +/- 9.21; 1S-M = 20.4 +/- 3.9; 2S-NM = 20.5 +/- 7.7; 2S-M = 21.3 +/- 4.4. Statistical analysis using a two-way analysis of variance showed no difference at the 0.05 level of significance. Pairwise comparison using the Tukey method showed that neither technique (one-step vs two-step) nor movement is a significant factor. These results showed that low seating pressure will not cause any greater distortions in the two-step impression technique than in the one-step technique, and minor movement during the setting of the impression material will no cause distortion.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8710707

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.

Authors:  Stephania Caroline Rodolfo Silva; Aion Mangino Messias; Filipe de Oliveira Abi-Rached; Raphael Freitas de Souza; José Maurício Dos Santos Nunes Reis
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

2.  Comparative analysis of different impression techniques in relation to single tooth impression.

Authors:  Aman Merchant; Subhabrata Maiti; V Ashok; Dhanraj M Ganapathy
Journal:  Bioinformation       Date:  2020-12-31

3.  Avoidance of Interaction between Impression Materials and Tooth Surface Treated for Immediate Dentin Sealing: An In Vitro Study.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Giovanna Murmura; Giorgio Di Vincenzo; Mario Semenza; Sergio Caputi; Tonino Traini
Journal:  Materials (Basel)       Date:  2019-10-22       Impact factor: 3.623