Literature DB >> 8707042

[Magnetocardiography for assessment of fetal heart actions].

P van Leeuwen1, M Schüssler, H Bettermann, S Lange, W Hatzmann.   

Abstract

Magnetocardiography provides a new, alternative method for fetal surveillance. This method allows the registration of changes in the magnetic field produced by the fetal cardiac system. In comparison to fetal ECG, the fetal magnetocardiogram (fMCG) is not affected by intermediate tissue, in particular by the insulating effect of the vernix caseosa. Furthermore fMCG's with a good signal noise ratio can be obtained in the second trimester. A multichannel biomagnetometer allows the non-invasive measurement of the magnetic signals produced by the fetus. Examples of dta and evaluation techniques are given. Signal processing software allows the identification of all fetal beats in a data set, permitting the calculation of an averaged beat and the evaluation of signal morphology and cardiac time intervals. Furthermore it is possible to produce a beat to beat time series with high temporal resolution, making the evaluation of heart rate variability with measures from the time, frequency, and phase domain accessible. Particularly the latter are of interest in investigating changes in temporal complexity of the fetal cardiac system. Magnetocardiography thus holds the promise of improved antenatal surveillance as of the second trimester.

Entities:  

Mesh:

Year:  1995        PMID: 8707042     DOI: 10.1055/s-2007-1023539

Source DB:  PubMed          Journal:  Geburtshilfe Frauenheilkd        ISSN: 0016-5751            Impact factor:   2.915


  5 in total

1.  Has magnetocardiography a clinical future?

Authors:  H D Esperer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-09

2.  [Has the magnetocardiography a clinical future?].

Authors:  H D Esperer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-09

3.  [Fetal magnetocardiography].

Authors:  P van Leeuwen
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-09

Review 4.  Cardiac arrhythmias in the human fetus.

Authors:  C S Kleinman; R A Nehgme
Journal:  Pediatr Cardiol       Date:  2004 May-Jun       Impact factor: 1.655

5.  Dependency of magnetocardiographically determined fetal cardiac time intervals on gestational age, gender and postnatal biometrics in healthy pregnancies.

Authors:  Peter Van Leeuwen; Silke Lange; Anita Klein; Daniel Geue; Dietrich HW Grönemeyer
Journal:  BMC Pregnancy Childbirth       Date:  2004-04-02       Impact factor: 3.007

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.