Physiology and pharmacokinetics of a novel hemoglobin-based oxygen carrier in humans.

G S Hughes1, E J Antal, P K Locker, S F Francom, W J Adams, E E Jacobs.   

Abstract

OBJECTIVE: To evaluate the physiology and pharmacokinetics of a novel hemoglobin-based oxygen carrier of bovine origin.
DESIGN: Randomized, single-blind, placebo-controlled, dose-escalation study.
SETTING: The Upjohn Research Clinics (Kalamazoo, MI).
SUBJECTS: Normal healthy adult men between the ages of 18 and 45 yrs. There were 18 subjects who received active treatment and 23 controls.
INTERVENTIONS: All subjects had phlebotomy of 15% of blood volume (performed in <15 mins) followed by isovolemic hemodilution (3:1, Ringer's lactate to the volume of whole blood removed) over a 90-min period, and either active drug (polymerized bovine hemoglobin) or a control infusion of lactated Ringer's solution (each infusion given over a total of 4.3 hrs). The subjects randomized to active treatment received a loading dose and a continuous infusion of polymerized bovine hemoglobin for a total dose of 16.5, 24.1, 30.2, 38.0, or 45.0 g. All subjects had an indwelling radial artery catheter (for blood pressure and arterial blood gas measurements), determination of cardiac function (by impedance plethysmography), serial pulmonary function tests (spirometry and diffusion capacity), and metabolic cart measurements.
MEASUREMENTS AND MAIN RESULTS: Pharmacokinetics of the plasma bovine hemoglobin demonstrated that the elimination of the hemoglobin-based oxygen carrier was a linear, first-order process and that there was no renal excretion. Peak plasma concentrations were between 1 to 2 g/dL and plasma half-life approached 20 hrs at the highest doses given. Diffusion capacity of oxygen was increased up to 20% above baseline in the 38.0 and 45.0 g groups in comparison with controls (approximately 14% below baseline) between 2 and 24 hrs after the infusion (p < .01). Other pulmonary function tests and arterial blood gas measurements were unremarkable. Arterial oxygen content and oxygen delivery tended to be greater in active groups than in controls.
CONCLUSIONS: The plasma concentrations of bovine hemoglobin were directly proportional to the doses administered. An increase in diffusion capacity paralleled the plasma bovine hemoglobin concentrations. Dosing of the hemoglobin-based oxygen carrier of bovine origin to a target plasma hemoglobin concentration can be achieved using pharmacokinetic principles with measurable effects on oxygen physiology.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8706450     DOI: 10.1097/00003246-199605000-00006

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  11 in total

1.  Recombinant hemoglobins as artificial oxygen carriers.

Authors:  Clara Fronticelli; Raymond C Koehler; William S Brinigar
Journal:  Artif Cells Blood Substit Immobil Biotechnol       Date:  2007

2.  Hemoglobin-based oxygen carriers in trauma care: scientific rationale for the US multicenter prehosptial trial.

Authors:  Ernest E Moore; Aaron M Cheng; Hunter B Moore; Tomohiko Masuno; Jeffrey L Johnson
Journal:  World J Surg       Date:  2006-07       Impact factor: 3.352

3.  Bovine haemoglobin is more potent than autologous red blood cells in restoring muscular tissue oxygenation after profound isovolaemic haemodilution in dogs.

Authors:  T Standl; P Horn; S Wilhelm; C Greim; M Freitag; U Freitag; A Sputtek; E Jacobs; J Schulte am Esch
Journal:  Can J Anaesth       Date:  1996-07       Impact factor: 5.063

4.  Decreased damage from transient focal cerebral ischemia by transfusion of zero-link hemoglobin polymers in mouse.

Authors:  Toshiaki Mito; Masaaki Nemoto; Herman Kwansa; Kenji Sampei; Murtuza Habeeb; Stephanie J Murphy; Enrico Bucci; Raymond C Koehler
Journal:  Stroke       Date:  2008-11-06       Impact factor: 7.914

5.  The USA Multicenter Prehosptial Hemoglobin-based Oxygen Carrier Resuscitation Trial: scientific rationale, study design, and results.

Authors:  Ernest E Moore; Jeffrey L Johnson; Frederick A Moore; Hunter B Moore
Journal:  Crit Care Clin       Date:  2009-04       Impact factor: 3.598

Review 6.  Hemoglobin substitutes.

Authors:  Kevin K Anbari; Jonathan P Garino; Colin F Mackenzie
Journal:  Eur Spine J       Date:  2004-05-27       Impact factor: 3.134

7.  Inhaled nitric oxide reverses cell-free hemoglobin-induced pulmonary hypertension and decreased lung compliance. Preliminary results.

Authors: 
Journal:  Crit Care       Date:  1997       Impact factor: 9.097

Review 8.  Comparison of the Pharmacokinetic Properties of Hemoglobin-Based Oxygen Carriers.

Authors:  Kazuaki Taguchi; Keishi Yamasaki; Toru Maruyama; Masaki Otagiri
Journal:  J Funct Biomater       Date:  2017-03-18

9.  ACVIM consensus statement on the treatment of immune-mediated hemolytic anemia in dogs.

Authors:  James W Swann; Oliver A Garden; Claire L Fellman; Barbara Glanemann; Robert Goggs; Dana N LeVine; Andrew J Mackin; Nathaniel T Whitley
Journal:  J Vet Intern Med       Date:  2019-03-07       Impact factor: 3.333

Review 10.  Alternatives to blood in the 21st century.

Authors:  Stephen M Cohn
Journal:  Crit Care       Date:  2004-06-14       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.