Automatic external defibrillators in the hospital as well?

A Destro1, M Marzaloni, S Sermasi, F Rossi.   

Abstract

When a cardiac arrest occurs in a non-intensive area of the hospital, the emergency response is not always adequate from the point of view of timeliness and technical quality. The aims of this study were evaluate an experimental programme to improve the CPR skills of staff operating in non-intensive areas of our general hospital and to test the usefulness of placing automatic external defibrillators (AEDs) within these areas. In the experimental phase, two AEDs were placed in 2 non-intensive wards of our hospital for 8 months. The staff of these wards received specific training in CPR and early defibrillation (CPR-D). The devices were used in 19 cases; for defibrillation in four cases of ventricular fibrillation (VF) (three patients were discharged alive from hospital), and for monitoring three supraventricular arrhythmias, one bradyarrhythmia and 11 cardiac rhythms during critical situations. In the implementation phase, four AEDs were indefinitely assigned to as many non-intensive awards. Periodical CPR-D courses and refresher exercises were run; the cardiology staff co-operated in the maintenance of the AEDs and in the registration of technical and clinical data. In the first period of this phase (9 months), AEDs were utilized in 24 cases by the ward-staff: in nine cases for VF (three patients were discharged alive from hospital) and in 15 cases for other rhythm detection in critical conditions. The number and the quality of these uses seem to confirm the favourable impact of the adoption of a more user-friendly defibrillator, such as an AED. The active co-operation between intensive and non-intensive staff was important to facilitate a quick activation of the chain of survival outside the intensive care units. We conclude that AEDs, which were developed for out-of-hospital use by non-physician operators, are suitable for use inside the hospital as well.

Entities:  

Mesh:

Year:  1996        PMID: 8701108     DOI: 10.1016/0300-9572(95)00914-0

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  4 in total

1.  Singapore Defibrillation Guidelines 2016.

Authors:  Chun Yue Francis Lee; Venkataraman Anantharaman; Swee Han Lim; Yih Yng Ng; Tek Siong Chee; Chong Meng Seet; Marcus Eng Hock Ong
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

Review 2.  In-hospital cardiac arrest: incidence, prognosis and possible measures to improve survival.

Authors:  Claudio Sandroni; Jerry Nolan; Fabio Cavallaro; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2006-09-22       Impact factor: 17.440

3.  The automatic external cardioverter-defibrillator.

Authors:  Antoni Martínez-Rubio; Gonzalo Barón-Esquivias
Journal:  Indian Pacing Electrophysiol J       Date:  2004-07-01

4.  Distribution and use of automated external defibrillators and their effect on return of spontaneous circulation in Danish hospitals.

Authors:  Mathilde Stærk; Kasper G Lauridsen; Kristian Krogh; Bo Løfgren
Journal:  Resusc Plus       Date:  2022-02-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.