Literature DB >> 8700027

Chelator effect on ion diffusion in ferrous-sulfate-doped gelatin gel dosimeters as analyzed by MRI.

W I Rae1, C A Willemse, M G Lötter, J S Engelbrecht, J C Swarts.   

Abstract

Ferrous-sulfate-doped gelatin gel dosimeters are useful tools for the measurement of three-dimensional absorbed radiation dose distributions. The diffusion of ferric ions through these gels causes degradation with time of the dose distribution image. It would be useful to reduce ferric ion diffusion without decreasing gel sensitivity. The amount of ferric ion diffusion is a function of the time delay after radiation, the gel temperature, and the gel concentration. These effects can be quantified by measuring the ferric ion diffusion coefficient. Determination of the diffusion coefficient by irradiating the lower section of a cylinder of gel, which was then imaged repeatedly over time with a clinical magnetic resonance imager, is described. Analysis of the edge spread function formed at each of several times after irradiation by drawing a profile over the imaged junction between the irradiated and unirradiated halves of the cylinder, gave estimates of the variance of the edge spread function. These variances were used to obtain an estimate of the ferric ion diffusion coefficient for the gel. A method of reducing ferric ion diffusion by adding a chelator and the cross linkage agent formaldehyde is suggested. The chelators investigated were 1,10 phenanthroline, xylenol orange, and bathophenanthroline disulfonic acid. These reduced diffusion to varying extents, and influenced the gel sensitivity. The diffusion coefficient in gels containing xylenol orange was found to be 0.44 mm2h-1. The gel sensitivity was 0.0093 s-1Gy-1. This compared with a diffusion coefficient of 0.82 mm2h-1 for the base line gel that did not contain formaldehyde or chelators. The sensitivity of this base line gel was 0.0129 s-1Gy-1. The addition of xylenol orange produced the most improved gel dosimeter of the gels studied. This gel had a decreased ferric ion diffusion coefficient and a decreased sensitivity. It was still sensitive enough to be useful.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8700027     DOI: 10.1118/1.597787

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA-GTA Fricke Gel Dosimeters: A Spectrophotometric Study.

Authors:  Martina Scotti; Paolo Arosio; Elisa Brambilla; Salvatore Gallo; Cristina Lenardi; Silvia Locarno; Francesco Orsini; Emanuele Pignoli; Luca Pedicone; Ivan Veronese
Journal:  Gels       Date:  2022-03-23

2.  MAGIC polymer gel for dosimetric verification in boron neutron capture therapy.

Authors:  Jouni Uusi-Simola; Sami Heikkinen; Petri Kotiluoto; Tom Serén; Tiina Seppälä; Iiro Auterinen; Sauli Savolainen
Journal:  J Appl Clin Med Phys       Date:  2007-04-30       Impact factor: 2.102

  2 in total