Literature DB >> 8699940

Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI.

G H Glover1, S K Lemieux, M Drangova, J M Pauly.   

Abstract

Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, whereas susceptibility and diffusion-related signal losses are larger in the second echo. An efficient dual-echo interleaved spiral sequence was developed for use with a conventional scanner. It uses a k-space trajectory that spirals out from the origin while the first echo is collected, then spirals back in while collecting the second echo. Decomposition of the data provides separate images of the inflow and T2-weighted components. Results demonstrate the decomposition with phantom experiments and with photic stimulation in normal volunteers.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8699940     DOI: 10.1002/mrm.1910350306

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Physiological noise effects on the flip angle selection in BOLD fMRI.

Authors:  J Gonzalez-Castillo; V Roopchansingh; P A Bandettini; J Bodurka
Journal:  Neuroimage       Date:  2010-11-10       Impact factor: 6.556

Review 2.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

3.  Functional brain imaging using a long intravenous half-life gadolinium-based contrast agent.

Authors:  D W Morton; B Keogh; K Lim; K R Maravilla
Journal:  AJNR Am J Neuroradiol       Date:  2006-08       Impact factor: 3.825

4.  Dynamics of the cerebral blood flow response to brief neural activity in human visual cortex.

Authors:  Jung Hwan Kim; Amanda J Taylor; Danny Jj Wang; Xiaowei Zou; David Ress
Journal:  J Cereb Blood Flow Metab       Date:  2019-08-20       Impact factor: 6.200

5.  The effect of flow on blood oxygen level dependent (R* 2 ) MRI of orthotopic lung tumors.

Authors:  Heling Zhou; Olivier Belzile; Zhang Zhang; Jo Wagner; Chul Ahn; James A Richardson; Debabrata Saha; Rolf A Brekken; Ralph P Mason
Journal:  Magn Reson Med       Date:  2019-01-30       Impact factor: 4.668

6.  Characterization and reduction of cardiac- and respiratory-induced noise as a function of the sampling rate (TR) in fMRI.

Authors:  Dietmar Cordes; Rajesh R Nandy; Scott Schafer; Tor D Wager
Journal:  Neuroimage       Date:  2013-12-16       Impact factor: 6.556

7.  Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI.

Authors:  Prantik Kundu; Souheil J Inati; Jennifer W Evans; Wen-Ming Luh; Peter A Bandettini
Journal:  Neuroimage       Date:  2011-12-23       Impact factor: 6.556

8.  Investigating the spatiotemporal characteristics of the deoxyhemoglobin-related and deoxyhemoglobin-unrelated functional hemodynamic response across cortical layers in awake marmosets.

Authors:  Cecil Chern-Chyi Yen; Daniel Papoti; Afonso C Silva
Journal:  Neuroimage       Date:  2017-03-06       Impact factor: 6.556

Review 9.  Seven topics in functional magnetic resonance imaging.

Authors:  Peter A Bandettini
Journal:  J Integr Neurosci       Date:  2009-09       Impact factor: 2.117

10.  The neural basis of auditory temporal discrimination in girls with fragile X syndrome.

Authors:  Scott S Hall; Elizabeth Walter; Elena Sherman; Fumiko Hoeft; Allan L Reiss
Journal:  J Neurodev Disord       Date:  2009-03       Impact factor: 4.025

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.