The objective of this study was to establish a probe system for intraoperative quantitative leakage measurement during selective limb perfusion for adjuvant high-dose chemotherapy in patients with malignant melanomas. We used a portable gamma probe with digital display and investigated the physical properties in a phantom study simulating blood pool activity at different angles of the probe to the surface and different distances. In 20 patients the limb circulation was surgically separated from the systemic blood circulation, and the limb was then selectively perfused (cytostatics added) for 60 min. Initially, 15 MBq technetium-99m labelled autologous red blood cells was injected into the limb circulation, and an equal amount was kept as a standard. Every 10 min, blood samples were drawn from the body circulation and count rates were simultaneously measured by the probe system at the lower end of the sternal body. At the end of perfusion, the circulation of the limb was reconnected, the standard injected into the systemic circulation, and a blood sample drawn after 10 min. All blood samples were counted for calculation of leakage in terms of percent of the injected dose, and the results compared with the intraoperative count rates of the probe system. In the range of leakage observed in this study (0%-86%), the count rate of the probe system (corrected for blood volume, i.e. for body surface) correlated with the results of conventional measurement (r=0.92) according to the equation: %leakage=counts per sx[1.2xbody surface (m2)-1.19]. In conclusion, the use of the described probe system is a feasible approach for leakage quantification which continuously yields data during selective limb perfusion.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8698058     DOI: 10.1007/bf00833388

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  20 in total

1.  The leakage factor in regional perfusion with chemotherapeutic agents.

Authors:  J S STEHLIN; R L CLARK; E C WHITE; J E HEALEY; W C DEWEY; S BEERSTECHER
Journal:  Arch Surg       Date:  1960-06

2.  The use of a hand-held gamma detector improves the safety of isolated limb perfusion.

Authors:  A Sardi; J P Minton; C Mojzisik; C A Nieroda; P J Ferrara; G H Hinkle; M O Thurston; E W Martin
Journal:  J Surg Oncol       Date:  1989-07       Impact factor: 3.454

Review 3.  Hyperthermic isolation limb perfusion for malignant melanoma: a review.

Authors:  D G Coit
Journal:  Cancer Invest       Date:  1992       Impact factor: 2.176

4.  [Improved intraoperative leak control in cytostatic drug isolation perfusion of tumors of the extremities].

Authors:  M Manner; H Sinn; H Bubeck; C Kettelhack; P Schlag
Journal:  Langenbecks Arch Chir       Date:  1990

5.  Regional isolation perfusion in melanoma of the limbs; accomplishments, unsolved problems, future.

Authors:  B B Kroon
Journal:  Eur J Surg Oncol       Date:  1988-04       Impact factor: 4.424

6.  Intraoperative detection of pheochromocytoma with iodine-125 labelled meta-iodobenzylguanidine: a feasibility study.

Authors:  M Ricard; F Tenenbaum; M Schlumberger; J P Travagli; J Lumbroso; Y Revillon; C Parmentier
Journal:  Eur J Nucl Med       Date:  1993-05

7.  [Quantitative radionuclide leakage control during isolated limb perfusion].

Authors:  H J Sprenger; J Markwardt; P M Schlag
Journal:  Nuklearmedizin       Date:  1994-12       Impact factor: 1.379

8.  Prophylactic hyperthermic limb perfusion in stage I melanoma.

Authors:  J E Krige; H S King; R M Strover
Journal:  Eur J Surg Oncol       Date:  1988-08       Impact factor: 4.424

9.  Dual-detector probe for surgical tumor staging.

Authors:  T S Hickernell; H B Barber; H H Barrett; J M Woolfenden
Journal:  J Nucl Med       Date:  1988-06       Impact factor: 10.057

10.  The role of regional hyperthermic cytostatic perfusion in the treatment of extremity melanoma.

Authors:  F Ghussen; I Krüger; W Groth; H Stützer
Journal:  Cancer       Date:  1988-02-15       Impact factor: 6.860

View more
  1 in total

Review 1.  A comprehensive overview of radioguided surgery using gamma detection probe technology.

Authors:  Stephen P Povoski; Ryan L Neff; Cathy M Mojzisik; David M O'Malley; George H Hinkle; Nathan C Hall; Douglas A Murrey; Michael V Knopp; Edward W Martin
Journal:  World J Surg Oncol       Date:  2009-01-27       Impact factor: 2.754

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.