Literature DB >> 869596

Aerosol inhalation and depth of deposition in the human lung. The effect of airway obstruction and tidal volume inhaled.

D Pavia, M Thomson, H S Shannon.   

Abstract

Ten patients with chronic bronchitis, whose FEV1.0 varied between 0.48 and 3.00 1, inhaled uniform 5-micronm particles tagged with technetium-99 in tidal volumes (VT) varying between 750 and 1830 ml. Their chests were scanned after inhalation to ascertain depth of deposition of the particles, and clearance from the lungs was monitored for 5 hr by serial whole-lung gamma counting. A significant inverse relationship (P less than .05) was found between depth of deposition after inhalation (D), measured horizontally across the lung as percentage per inch, and rate of clearance of the particles (5-hr retention [%] = 100- % cleared at 5 hr=69.12-3.02D). This confirmed previous findings. The depth of deposition depended directly on the FEV1.0 and VT (5-hr retention [%] = 0.026VT + 12.67FEV1.0-4.13); this resulted in a 14%-75% range for 5-hr retention. Regression slopes for VT and FEV1.0 were independently significant (P less than .05). The findings suggest that, as commonly administered at present, the therapeutic efficiency of most drugs given be aerosol will be reduced in proportion to the degree of airway obstruction as measured by the FEV1.0. The efficiency can be enhanced by increasing the depth of inspiration of the aerosol.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 869596     DOI: 10.1080/00039896.1977.10667269

Source DB:  PubMed          Journal:  Arch Environ Health        ISSN: 0003-9896


  8 in total

1.  Spirometric data and penetration of particles to the alveoli.

Authors:  M Svartengren; E Hassler; K Philipson; P Camner
Journal:  Br J Ind Med       Date:  1986-03

Review 2.  Deposition, retention, and clearance of inhaled particles.

Authors:  M Lippmann; D B Yeates; R E Albert
Journal:  Br J Ind Med       Date:  1980-11

Review 3.  Lung mucus production and mucociliary clearance: methods of assessment.

Authors:  S W Clarke; D Pavia
Journal:  Br J Clin Pharmacol       Date:  1980-06       Impact factor: 4.335

4.  Effect of ipratropium bromide on mucociliary clearance and pulmonary function in reversible airways obstruction.

Authors:  D Pavia; J R Bateman; N F Sheahan; S W Clarke
Journal:  Thorax       Date:  1979-08       Impact factor: 9.139

5.  Investigations of an optimal inhaler technique with the use of urinary salbutamol excretion as a measure of relative bioavailability to the lung.

Authors:  M Hindle; D A Newton; H Chrystyn
Journal:  Thorax       Date:  1993-06       Impact factor: 9.139

6.  Effect of an extension tube on the bronchodilator efficacy of terbutaline delivered from a metered dose inhaler.

Authors:  S A Gomm; N P Keaney; N J Winsey; T B Stretton
Journal:  Thorax       Date:  1980-07       Impact factor: 9.139

7.  Aminophylline and mucociliary clearance in patients with irreversible airflow limitation.

Authors:  M G Pearson; D Ahmad; M J Chamberlain; W K Morgan; S Vinitski
Journal:  Br J Clin Pharmacol       Date:  1985-12       Impact factor: 4.335

Review 8.  Aerosol delivery systems for bronchial asthma.

Authors:  P L Ariyananda; J E Agnew; S W Clarke
Journal:  Postgrad Med J       Date:  1996-03       Impact factor: 2.401

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.