Literature DB >> 8694309

The effects of varying volumes of crystalloid administration before cesarean delivery on maternal hemodynamics and colloid osmotic pressure.

G E Park1, M A Hauch, F Curlin, S Datta, A M Bader.   

Abstract

The value of intravenous crystalloid administration in preventing spinal-induced hypotension in the parturient has recently been questioned. Also, the association between increasing crystalloid volume and decreasing postpartum colloid osmotic pressure (COP) raises concern regarding the risk of maternal and fetal pulmonary edema. To study the dose-response effect of varying amounts of crystalloid volume prior to spinal anesthesia, we measured maternal hemodynamic variables and maternal and fetal COP in three groups of healthy parturients receiving spinal anesthesia for elective cesarean delivery. Fifty-five parturients were randomized in a double-blind fashion to receive one of 10, 20, or 30 mL/kg of crystalloid volumes prior to induction of spinal anesthesia. Measurements included mean arterial blood pressure (MAP), cardiac index (CI), and systemic vascular resistance index (SVRI) recorded using noninvasive thoracic impedance monitoring until delivery. Maternal and neonatal COP were measured. All groups showed declines in MAP and SVRI from baseline at 5 min after spinal anesthesia, but the amount of decline did not differ among groups. Total ephedrine and additional intravenous (i.v.) fluid administered did not differ among groups. The 20- and 30- mL/kg groups showed a larger decline in maternal COP than the 10-mL/kg group; no differences in neonatal COP were seen with varying preload. We conclude that increasing the amount of i.v. crystalloid administered to 30 mL/kg in the healthy parturient does not significantly alter maternal hemodynamics or ephedrine requirements after spinal anesthesia and has no apparent benefit.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8694309     DOI: 10.1097/00000539-199608000-00017

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  11 in total

1.  Perioperative tissue thickness measurement by a new miniature ultrasound device.

Authors:  J Schumacher; W Eichler; O Bauer; K F Klotz
Journal:  J Clin Monit Comput       Date:  1998-12       Impact factor: 2.502

2.  Comparison of effects of rapid colloid loading before and after spinal anesthesia on maternal hemodynamics and neonatal outcomes in cesarean section.

Authors:  Koichi Nishikawa; Naho Yokoyama; Shigeru Saito; Fumio Goto
Journal:  J Clin Monit Comput       Date:  2007-01-30       Impact factor: 2.502

3.  Techniques for preventing hypotension during spinal anaesthesia for caesarean section.

Authors:  Cheryl Chooi; Julia J Cox; Richard S Lumb; Philippa Middleton; Mark Chemali; Richard S Emmett; Scott W Simmons; Allan M Cyna
Journal:  Cochrane Database Syst Rev       Date:  2020-07-01

4.  Prevention of altered hemodynamics after spinal anesthesia: A comparison of volume preloading with tetrastarch, succinylated gelatin and ringer lactate solution for the patients undergoing lower segment caesarean section.

Authors:  Tapobrata Mitra; Anjan Das; Saikat Majumdar; Tapas Bhattacharyya; Rahul Deb Mandal; Bimal Kumar Hajra
Journal:  Saudi J Anaesth       Date:  2014-10

Review 5.  Intravascular volume therapy in adults: Guidelines from the Association of the Scientific Medical Societies in Germany.

Authors:  Gernot Marx; Achim W Schindler; Christoph Mosch; Joerg Albers; Michael Bauer; Irmela Gnass; Carsten Hobohm; Uwe Janssens; Stefan Kluge; Peter Kranke; Tobias Maurer; Waltraut Merz; Edmund Neugebauer; Michael Quintel; Norbert Senninger; Hans-Joachim Trampisch; Christian Waydhas; Rene Wildenauer; Kai Zacharowski; Michaela Eikermann
Journal:  Eur J Anaesthesiol       Date:  2016-07       Impact factor: 4.330

6.  Effect of anaesthetic technique on neonatal morbidity in emergency caesarean section for foetal distress.

Authors:  Ipek Saadet Edipoglu; Fatma Celik; Elif Cirakoglu Marangoz; Gulin Haroglu Orcan
Journal:  PLoS One       Date:  2018-11-16       Impact factor: 3.240

7.  SPINAL ANAESTHESIA-INDUCED HYPOTENSION IN OBSTETRICS: PREVENTION AND THERAPY.

Authors:  Ivan Šklebar; Tonka Bujas; Dubravko Habek
Journal:  Acta Clin Croat       Date:  2019-06       Impact factor: 0.780

8.  The effects of intravenous ephedrine during spinal anesthesia for cesarean delivery: a randomized controlled trial.

Authors:  Iclal Ozdemir Kol; Kenan Kaygusuz; Sinan Gursoy; Ali Cetin; Zeki Kahramanoglu; Fikret Ozkan; Caner Mimaroglu
Journal:  J Korean Med Sci       Date:  2009-09-23       Impact factor: 2.153

9.  The Effects of Hydroxyethyl Starch 6% and Crystalloid on Volume Preloading Changes following Spinal Anesthesia.

Authors:  Masoud Saghafinia; Alireza Jalali; Mahnaz Eskandari; Nahid Eskandari; Marzieh Lak
Journal:  Adv Biomed Res       Date:  2017-09-21

10.  Perfusion index as a predictor of hypotension following spinal anaesthesia in lower segment caesarean section.

Authors:  Devika Rani Duggappa; Mps Lokesh; Aanchal Dixit; Rinita Paul; R S Raghavendra Rao; P Prabha
Journal:  Indian J Anaesth       Date:  2017-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.