Literature DB >> 8694301

Carbon dioxide elimination measures resolution of experimental pulmonary embolus in dogs.

P H Breen1, B Mazumdar, S C Skinner.   

Abstract

Patients with severe pulmonary embolism can suffer progressive hypercapnia refractory to supramaximal mechanical ventilation, and may require open-thoracic or transvenous emergency embolectomy in addition to anticoagulation and/or thrombolysis. The functional recovery of gas exchange would be signaled by an increase in pulmonary CO2 elimination and decrease in CO2 retention; such data could guide the course of operative embolectomy. Accordingly, we studied five chloralose-urethane anesthetized, mechanically ventilated dogs with open thoraces in which the right pulmonary arteries (RPAs) were reversibly occluded with cloth snares. After waiting for steady state, we abruptly released the snare to restore RPA perfusion and experimentally simulate resolution of pulmonary embolism. For 70 min we serially measure the CO2 volume exhaled per breath (VCO2,br), arterial, mixed venous, and end-tidal PCO2 (PACO2, PVCO2, PETCO2), cardiac output (QT), and the alveolar dead space fraction (VDalv/VTalv = [PaCO2 - PETCO2/PaCO2). RPA reperfusion caused VCO2,br to significantly and abruptly increase from 8.9 +/- 2.7 to 11.6 +/- 3.6 mL; 70 min later VCO2,br had returned to baseline. PaCO2 and PVCO2 steadily decreased during 70 min of RPA reperfusion. PETCO2 increased from 25 +/- 5 to 33 +/- 5 mm Hg immediately after RPA reperfusion, as VDalv/VTalv decreased from 54% +/- 10% to 32% +/- 12%, but PETCO2 was still significantly greater than baseline at 70 min of RPA reperfusion. QT did not significantly change. We conclude that intraoperative measurement of VCO2,br should immediately detect and follow the resolution of CO2 retention in the lung and peripheral tissues after RPA reperfusion. PETCO2 could not detect the decrease of VCO2,br back to baseline because PETCO2 does not measure exhaled volume or the PCO2 waveform.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8694301     DOI: 10.1097/00000539-199608000-00009

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  3 in total

Review 1.  Non-steady state monitoring by respiratory gas exchange.

Authors:  P H Breen; S A Isserles; U Z Taitelman
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

2.  Measurement of pulmonary CO2 elimination must exclude inspired CO2 measured at the capnometer sampling site.

Authors:  P H Breen; E R Serina; S J Barker
Journal:  J Clin Monit       Date:  1996-05

Review 3.  Carbon dioxide kinetics and capnography during critical care.

Authors:  C T Anderson; P H Breen
Journal:  Crit Care       Date:  2000-07-12       Impact factor: 9.097