PURPOSE: To determine the relationship between dose, volume, and the incidence of hip stiffness in patients who received conformal neutron irradiation for prostate cancer. METHODS AND MATERIALS: A series of dose-searching studies using neutron irradiation for prostate cancer were performed to determine the optimal dose, fraction size, field size, technique, and proportions of photon and neutron dose. Neutron doses ranged from 9 to 20 Gy and photon doses ranged from 0 to 38 Gy. Data were analyzed by using a hip stiffness grading scale. RESULTS: Hip stiffness was recorded on follow-up examination in 30% of patients (40 out of 132) treated with fast neutrons or mixtures of fast neutron and photon radiation for prostate cancer. Hip stiffness was categorized as none (Grade 0, 92 patients), mild (Grade 1, 24 patients), moderate (Grade 2, 10 patients), or severe (Grade 3, 6 patients). The incidence of hip stiffness differed significantly by dose and volume in the five dose levels studied (p < 0.001). CONCLUSIONS: By using a mixture of conformal neutron and photon irradiation and limiting the total neutron dose to less than 13 Gy, hip stiffness toxicity could be reduced to acceptable levels.
PURPOSE: To determine the relationship between dose, volume, and the incidence of hip stiffness in patients who received conformal neutron irradiation for prostate cancer. METHODS AND MATERIALS: A series of dose-searching studies using neutron irradiation for prostate cancer were performed to determine the optimal dose, fraction size, field size, technique, and proportions of photon and neutron dose. Neutron doses ranged from 9 to 20 Gy and photon doses ranged from 0 to 38 Gy. Data were analyzed by using a hip stiffness grading scale. RESULTS:Hip stiffness was recorded on follow-up examination in 30% of patients (40 out of 132) treated with fast neutrons or mixtures of fast neutron and photon radiation for prostate cancer. Hip stiffness was categorized as none (Grade 0, 92 patients), mild (Grade 1, 24 patients), moderate (Grade 2, 10 patients), or severe (Grade 3, 6 patients). The incidence of hip stiffness differed significantly by dose and volume in the five dose levels studied (p < 0.001). CONCLUSIONS: By using a mixture of conformal neutron and photon irradiation and limiting the total neutron dose to less than 13 Gy, hip stiffness toxicity could be reduced to acceptable levels.
Authors: Michael J Zelefsky; Marisa A Kollmeier; Elan Gorshein; Xin Pei; Marina Torres; Sean McBride; Laura Happersett; Gil'ad N Cohen; Yoshiya Yamada Journal: Radiother Oncol Date: 2016-10-15 Impact factor: 6.280
Authors: Patricia Mae G Santos; Andrew R Barsky; Wei-Ting Hwang; Curtiland Deville; Xingmei Wang; Stefan Both; Justin E Bekelman; John P Christodouleas; Neha Vapiwala Journal: Cancer Date: 2019-09-10 Impact factor: 6.860