Literature DB >> 8686911

Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small-volume online sensor.

O Niwa1, K Torimitsu, M Morita, P Osborne, K Yamamoto.   

Abstract

An online sensor with a low detection limit for L-glutamate was developed in order to monitor the change in the extracellular L-glutamate concentration as a result of stimulated release from cultured nerve cells. The sensor consisted of a microdialysis (MD) probe fixed at the manipulator, a small-volume L-glutamate oxidase enzymatic reactor (0.75 mm i.d. and 2.5 cm long), and an electrochemical detector in a thin-layer radial flow cell with an active volume of 70-340 nL. Glassy carbon bulk or carbon film ring-disk electrodes were used as detectors by modifying them with Os poly(vinylpyridine) mediator containing horseradish peroxidase. The overall efficiency of L-glutamate detection with the sensor is 94% under optimum conditions, due to an efficient enzymatic reaction in the reactor and a high conversion efficiency in the radial flow cell. As a result, we achieved a sensitivity of 24.3 nA/muM and a detection limit of 7.2 nM (S/N = 3). The effect of interferents such as L-ascorbic acid can be minimized effectively by applying a low potential to the electrode for hydrogen peroxide detection (O mV) and via the ring-disk electrode geometry by using the disk for preoxidation. In the in vitro experiment, an MD probe for sampling was connected to a manipulator that controls distance between the probe and the stimulated cells. The cells were stimulated by KCl in a glass capillary or electrically with microarray film electrodes fabricated on a substrate. By using the sensor, we can monitor L-glutamate concentration changes at the submicromolar level caused by KCl stimulation of a single nerve cell and micromolar L-glutamate concentration increases caused by electrical stimulation of a brain slice. An increase in L-glutamate concentration can also be measured by positioning the probe near the cell that is connected synaptically to the stimulated cell.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8686911     DOI: 10.1021/ac951154d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Pharmacokinetic and metabolism studies using microdialysis sampling.

Authors:  D K Hansen; M I Davies; S M Lunte; C E Lunte
Journal:  J Pharm Sci       Date:  1999-01       Impact factor: 3.534

2.  Lactate as a biomarker for sleep.

Authors:  Erik Naylor; Daniel V Aillon; Brian S Barrett; George S Wilson; David A Johnson; Donna A Johnson; Hans P Harmon; Seth Gabbert; Peter A Petillo
Journal:  Sleep       Date:  2012-09-01       Impact factor: 5.849

3.  Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor.

Authors:  Varun Lingaiah Kopparthy; Siva Mahesh Tangutooru; Eric J Guilbeau
Journal:  Bioengineering (Basel)       Date:  2015-01-12

4.  Carbon Felt-Based Bioelectrocatalytic Flow-Through Detectors: 2,6-Dichlorophenol Indophenol and Peroxidase Coadsorbed Carbon-Felt for Flow-Amperometric Determination of Hydrogen Peroxide.

Authors:  Yue Wang; Yasushi Hasebe
Journal:  Materials (Basel)       Date:  2014-02-12       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.