We used a microbore reversed phase column for acetonitrile/0.1% aqueous TFA gradient elution separation of peptides with the detection of their copper complexes by electrochemical detection. The copper complexes are formed in a short (1 or 1.5 min) postcolumn reactor following mixing of the eluent with the postcolumn reaction phase. Detection can be at an upstream anode or a downstream cathode of a dual-electrode electrochemical detector. The following parameters have been investigated for their effect on the sensitivity and the selectivity of the procedure: postcolumn pH, buffer type, temperature, reaction time, and anode potential. Of the 23 bioactive peptides used, there are several that fall into classes according to their chemical and electrochemical behavior with copper(II): those with a blocked terminal amine, those with aspartate in the third position, those that have an electroactive amino acid, and those that have a cyclic structure formed by the amide backbone through a Cys-Cys disulfide bridge. Depending on these attributes, the operating parameters have an influence on the sensitivity of the determination. Among the more well-defined results are the following. Uncomplicated peptides with a free amine terminus react rapidly in the postcolumn reactor and give signals in the range predicted by theory. There is evidence that longer peptides, and those with a blocked amine terminus, have a sensitivity limited by kinetic factors. The oxidations of tyrosine and tryptophan in peptides are dramatically influenced by buffer type at pH 9.8. At pH 8.0, there is no signal from several peptides in phosphate buffer, while in borate there is a signal.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8686905     DOI: 10.1021/ac00115a033

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Techniques for neuropeptide determination.

Authors:  Mats Sandberg; Stephen G Weber
Journal:  Trends Analyt Chem       Date:  2003-09       Impact factor: 12.296

2.  Evaluation of an on-capillary copper complexation methodology for the investigation of in vitro metabolism of dynorphin A 1-17.

Authors:  Courtney D Kuhnline; Susan M Lunte
Journal:  J Sep Sci       Date:  2010-08       Impact factor: 3.645

3.  The Rotating Ring-Disk Electrochemistry of the Copper(II) Complex of Thyrotropin-releasing Hormone.

Authors:  Rong Meng; Stephen G Weber
Journal:  J Electroanal Chem (Lausanne)       Date:  2007-02-15       Impact factor: 4.464

4.  Analysis of the performance of a flow reactor for use with microcolumn HPLC.

Authors:  Amy T Beisler; Eskil Sahlin; Kathleen E Schaefer; Stephen G Weber
Journal:  Anal Chem       Date:  2004-02-01       Impact factor: 6.986

Review 5.  Electroosmotic perfusion of tissue: sampling the extracellular space and quantitative assessment of membrane-bound enzyme activity in organotypic hippocampal slice cultures.

Authors:  Yangguang Ou; Juanfang Wu; Mats Sandberg; Stephen G Weber
Journal:  Anal Bioanal Chem       Date:  2014-08-29       Impact factor: 4.142

6.  Carbon Fiber/Epoxy Composite Ring-disk Electrode: Fabrication, Characterization and Application to Electrochemical Detection in Capillary High Performance Liquid Chromatography.

Authors:  Xiaomi Xu; Stephen G Weber
Journal:  J Electroanal Chem (Lausanne)       Date:  2009-05-15       Impact factor: 4.464

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.