Literature DB >> 8686883

Thrombogenic properties of untreated and poly(ethylene oxide)-modified polymeric matrices useful for preparing intraarterial ion-selective electrodes.

C Espadas-Torre1, M E Meyerhoff.   

Abstract

In vitro platelet adhesion studies are used to compare the thrombogenic properties of various polymer matrices useful for preparing implantable ion-selective membrane electrodes. Conventional plasticized poly(vinyl chloride) and alternate polyurethane materials (Tecoflex, Pellethane) doped with proton- (tridodecylamine) and potassium-selective (valinomycin) ionophores are shown to be potentially thrombogenic. Incorporation of high molecular weight block copolymers of poly(ethylene oxide) and poly(propylene oxide) (e.g., Pluronic F108 and Tetronic 1508) within ion-selective membranes reduces platelet adhesion. A more marked decrease in platelet adhesion is, however, observed when the Tecoflex-based membranes are coated with a thin photo-cross-linked layer of poly(ethylene oxide). Such surface-modified membranes are shown to retain potentiometric ion response properties (i.e., selectivity, response times, response slopes, etc.) essentially equivalent to untreated membranes.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8686883     DOI: 10.1021/ac00114a003

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Anti-inflammatory polymeric coatings for implantable biomaterials and devices.

Authors:  Amanda W Bridges; Andrés J García
Journal:  J Diabetes Sci Technol       Date:  2008-11

Review 2.  Biomaterials/tissue interactions: possible solutions to overcome foreign body response.

Authors:  Jacqueline M Morais; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  AAPS J       Date:  2010-02-09       Impact factor: 4.009

Review 3.  Mesh biocompatibility: effects of cellular inflammation and tissue remodelling.

Authors:  Karsten Junge; Marcel Binnebösel; Klaus T von Trotha; Raphael Rosch; Uwe Klinge; Ulf P Neumann; Petra Lynen Jansen
Journal:  Langenbecks Arch Surg       Date:  2011-04-01       Impact factor: 3.445

4.  A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response.

Authors:  Yoshinori Onuki; Upkar Bhardwaj; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2008-11

5.  Determination of the silver ion release from polyurethanes enriched with silver.

Authors:  R M Joyce-Wöhrmann; H Münstedt
Journal:  Infection       Date:  1999       Impact factor: 3.553

6.  A self-cleaning, mechanically robust membrane for minimizing the foreign body reaction: towards extending the lifetime of sub-Q glucose biosensors.

Authors:  A Kristen Means; Ping Dong; Fred J Clubb; Molly C Friedemann; Lydia E Colvin; Courtney A Shrode; Gerard L Coté; Melissa A Grunlan
Journal:  J Mater Sci Mater Med       Date:  2019-06-25       Impact factor: 3.896

Review 7.  Controlled release strategies for modulating immune responses to promote tissue regeneration.

Authors:  Courtney M Dumont; Jonghyuck Park; Lonnie D Shea
Journal:  J Control Release       Date:  2015-08-08       Impact factor: 9.776

8.  Distributed sensor and actuator networks for closed-loop bioelectronic medicine.

Authors:  Gauri Bhave; Joshua C Chen; Amanda Singer; Aditi Sharma; Jacob T Robinson
Journal:  Mater Today (Kidlington)       Date:  2021-03-06       Impact factor: 26.943

Review 9.  Biomaterials-based modulation of the immune system.

Authors:  Austin B Gardner; Simon K C Lee; Elliot C Woods; Abhinav P Acharya
Journal:  Biomed Res Int       Date:  2013-09-22       Impact factor: 3.411

Review 10.  New strategies to improve results of mesh surgeries for vaginal prolapses repair--an update.

Authors:  Fernando Goulart Fernandes Dias; Paulo Henrique Goulart Fernandes Dias; Alessandro Prudente; Cassio Riccetto
Journal:  Int Braz J Urol       Date:  2015 Jul-Aug       Impact factor: 1.541

  10 in total