Literature DB >> 8685937

How good is intercenter agreement in the identification of embolic signals in carotid artery disease?

H Markus1, J M Bland, G Rose, M Sitzer, M Siebler.   

Abstract

BACKGROUND AND
PURPOSE: There has been concern regarding the reproducibility of the detection of embolic signals, particularly in patients with carotid artery stenosis in whom the signals are of low intensity. No published studies have examined inter-center agreement in reporting specific embolic signals or the factors responsible for any lack of agreement. We examined reproducibility between two centers in which widely differing proportions of embolic signals have previously been reported in patients with carotid artery stenosis.
METHODS: Recordings from the middle cerebral artery of eight patients with ipsilateral carotid artery stenosis in whom embolic signals had been detected during a previously study were independently examined by three experienced observers in one center and by one experienced observer in another center. We calculated agreement within and between centers by estimating the probability that one observer would identify a specific embolic signal if other observers had identified it (a probability of 1 indicates complete agreement). The influence of different characteristics of the embolic signal on the probability of its detection as an embolic signal was determined.
RESULTS: A high level of agreement in the identification of specific embolic signals was found. This was similar between all observers (.90), between the three observers in one center (.89), and between observers in the two different centers (.94). The probability of detection was independently related to the relative intensity of the embolic signal (P<.0001). It was less (although significantly) independently related to the position of the embolic signal in the cardiac cycle (P=.02), with signals in systole being more reliably detected. There was no independent relationship between the probability of detection and either the duration of the embolic signal or the velocity at the maximum intensity increase. The use of threshold intensity as a criterion for embolic signal detection increased interobserver agreement but reduced the sensitivity in detecting signals.
CONCLUSIONS: The high level of interobserver agreement suggests that the technique is sufficiently reproducible for clinical use.

Entities:  

Mesh:

Year:  1996        PMID: 8685937     DOI: 10.1161/01.str.27.7.1249

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  7 in total

1.  Potential relevance of low-intensity microembolic signals by TCD monitoring.

Authors:  G Telman; E Sprecher; E Kouperberg
Journal:  Neurol Sci       Date:  2010-10-16       Impact factor: 3.307

2.  Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings.

Authors:  Katharina Marten; Andreas Grillhösl; Tobias Seyfarth; Silvia Obenauer; Ernst J Rummeny; Christoph Engelke
Journal:  Eur Radiol       Date:  2004-12-02       Impact factor: 5.315

3.  Web-based system for training and dissemination of a magnification chromoendoscopy classification.

Authors:  Mario Dinis-Ribeiro; Ricardo Correia; Cristina Santos; Sonia Fernandes; Ernesto Palhares; Rui-Almeida Silva; Pedro Amaro; Miguel Areia; Altamiro Costa-Pereira; Luis Moreira-Dias
Journal:  World J Gastroenterol       Date:  2008-12-14       Impact factor: 5.742

4.  The RoPE Score and Right-to-Left Shunt Severity by Transcranial Doppler in the CODICIA Study.

Authors:  Benjamin S Wessler; David M Kent; David E Thaler; Robin Ruthazer; Jennifer S Lutz; Joaquín Serena
Journal:  Cerebrovasc Dis       Date:  2015-07-11       Impact factor: 2.762

5.  Ischemia after carotid endarterectomy: comparison between transcranial Doppler sonography and diffusion-weighted MR imaging.

Authors:  M Müller; W Reiche; P Langenscheidt; J Hassfeld; T Hagen
Journal:  AJNR Am J Neuroradiol       Date:  2000-01       Impact factor: 3.825

6.  Vitamin E and respiratory tract infections in elderly nursing home residents: a randomized controlled trial.

Authors:  Simin Nikbin Meydani; Lynette S Leka; Basil C Fine; Gerard E Dallal; Gerald T Keusch; Maria Fiatarone Singh; Davidson H Hamer
Journal:  JAMA       Date:  2004-08-18       Impact factor: 56.272

7.  Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery.

Authors:  Jakub Kaczynski; Rachel Home; Karen Shields; Matthew Walters; William Whiteley; Joanna Wardlaw; David E Newby
Journal:  Cardiovasc Ultrasound       Date:  2018-09-11       Impact factor: 2.062

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.