Literature DB >> 8682528

Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation.

K Yoshida1, K Horch.   

Abstract

This paper describes a closed-loop functional neuromuscular stimulation system that uses afferent neural activity from muscle spindle fibers as feedback for controlling position of the ankle joint. Ankle extension against a load was effected by neural stimulation through a dual channel intrafascicular electrode of a fascicle of the tibial nerve that innervated the gastrocnemius muscle. Ankle joint angle was estimated from recordings of tibialis anterior and lateral gastrocnemius spindle fiber activity made with dual channel intrafascicular electrodes. Experiments were conducted in neurally intact anesthetized cats and in unanesthetized decerebrate cats to demonstrate the feasibility of this system. The system was able to reach and maintain a fixed target ankle position in the presence of a varying external moment ranging in magnitude between 7.3 and 22 N-cm opposing the action of the ankle extensor, as well as track a sinusoidal target ankle position up to a frequency of 1 Hz in the presence of a constant magnitude 22- or 37-N-cm external moment.

Entities:  

Mesh:

Year:  1996        PMID: 8682528     DOI: 10.1109/10.481986

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  Adaptive fuzzy control of electrically stimulated muscles for arm movements.

Authors:  S Micera; A M Sabatini; P Dario
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Model-based ankle joint angle tracing by cuff electrode recordings of peroneal and tibial nerves.

Authors:  Chou-Ching K Lin; Ming-Shaung Ju; Hang-Shing Cheng
Journal:  Med Biol Eng Comput       Date:  2007-02-02       Impact factor: 2.602

3.  Improved decoding of limb-state feedback from natural sensors.

Authors:  J B Wagenaar; V Ventura; D J Weber
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

4.  A phantom axon setup for validating models of action potential recordings.

Authors:  Olivier Rossel; Fabien Soulier; Serge Bernard; David Guiraud; Guy Cathébras
Journal:  Med Biol Eng Comput       Date:  2016-03-25       Impact factor: 2.602

5.  Motion control of the rabbit ankle joint with a flat interface nerve electrode.

Authors:  Hyun-Joo Park; Dominique M Durand
Journal:  Muscle Nerve       Date:  2015-09-07       Impact factor: 3.217

6.  Model-based development of neuroprosthesis for paraplegic patients.

Authors:  R Riener
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-05-29       Impact factor: 6.237

Review 7.  Neuroprosthetic technology for individuals with spinal cord injury.

Authors:  Jennifer L Collinger; Stephen Foldes; Tim M Bruns; Brian Wodlinger; Robert Gaunt; Douglas J Weber
Journal:  J Spinal Cord Med       Date:  2013-07       Impact factor: 1.985

8.  Spike sorting of muscle spindle afferent nerve activity recorded with thin-film intrafascicular electrodes.

Authors:  Milan Djilas; Christine Azevedo-Coste; David Guiraud; Ken Yoshida
Journal:  Comput Intell Neurosci       Date:  2010-03-30

Review 9.  The Evolution of Neuroprosthetic Interfaces.

Authors:  Dayo O Adewole; Mijail D Serruya; James P Harris; Justin C Burrell; Dmitriy Petrov; H Isaac Chen; John A Wolf; D Kacy Cullen
Journal:  Crit Rev Biomed Eng       Date:  2016

10.  Real-time control of hind limb functional electrical stimulation using feedback from dorsal root ganglia recordings.

Authors:  Tim M Bruns; Joost B Wagenaar; Matthew J Bauman; Robert A Gaunt; Douglas J Weber
Journal:  J Neural Eng       Date:  2013-03-15       Impact factor: 5.379

View more