Comparison of the polyethylene glycol antiglobulin test and the use of enzymes in antibody detection and identification.

R Reisner1, G Butler, K Bundy, S B Moore.   

Abstract

BACKGROUND: The polyethylene glycol indirect antiglobulin test for detection of red cell antibodies was compared with a proven, highly sensitive test system using papain. STUDY DESIGN AND METHODS: Parallel, prospective testing of 1508 samples with polyethylene glycol and with albumin and papain evaluated the sensitivity and specificity of polyethylene glycol. Retrospective analysis of antibody specificities was performed for the 2 years before and the 2 years after the institution of polyethylene glycol testing.
RESULTS: Of 1508 prospective screens, 53 (3.5%) had discordant results: 5 were positive only in polyethylene glycol and 48 were positive only in albumin and papain. Upon antibody identification, the 5 samples that were positive only in polyethylene glycol showed 1 anti-D, 2 warm autoantibodies, and 2 false-positive results. The 48 samples that were positive only in albumin and papain showed 1 each of the following: anti-Le(b); anti-P1; anti-S; high-titer, low-avidity antibody; and cold autoantibody; there were 43 false-positive results. False-positive results totaled 12 (0.8%) with polyethylene glycol and 53 (3.5%) with albumin and papain. The retrospective analysis of antibody specificity with polyethylene glycol showed a significant increase in the detection of Fy(a) and/or Fy(b) (p < 0.0002) and Jk(b) (p < 0.0002) antibodies and a decrease in the detection of Le(a) and/or Le(b) antibodies (p < 0.0002).
CONCLUSION: Polyethylene glycol retained the high sensitivity of the albumin and papain, while significantly lowering the number of false-positive results and decreasing the detection of antibodies of doubtful clinical significance.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8669077     DOI: 10.1046/j.1537-2995.1996.36696269504.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Increased detection of clinically significant antibodies and decreased incidence of delayed haemolytic transfusion reaction with the indirect antiglobulin test potentiated by polyethylene glycol compared to albumin: a Japanese study.

Authors:  Miho Okutsu; Hitoshi Ohto; Hiroyasu Yasuda; Kinuyo Kawabata; Satoshi Ono; Shunnichi Saito; Akiko Sugawara; Masami Kikuchi; Saori Miura; Youko Ishii; Kazuya Watanabe; Yuriko Tohyama; Kenneth E Nollet
Journal:  Blood Transfus       Date:  2010-11-26       Impact factor: 3.443

2.  Evaluation of a modified IAT-gel with polyethylenglycol (PEG) addition method for red blood cell antibody identification.

Authors:  L Gustafsson; A Wikman; J Lundahl
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

3.  Screening and identification of unexpected red cell antibodies by simultaneous LISS/Coombs and NaCl/Enzyme gel methods.

Authors:  Jeong Hwan Shin; Ja Young Lee; Jae Hyen Kim; Hye Ran Kim; Jeong Nyeo Lee
Journal:  J Korean Med Sci       Date:  2009-07-29       Impact factor: 2.153

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.