Literature DB >> 8668410

Thyroid screening for early discharged infants.

J G Saslow1, E M Post, C A Southard.   

Abstract

OBJECTIVE: As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely.
METHODS: During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994.
RESULTS: Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 microIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal.
CONCLUSIONS: Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8668410

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  1 in total

1.  Damaged goods?: an empirical cohort study of blood specimens collected 12 to 23 hours after birth in newborn screening in California.

Authors:  Hao Tang; Lisa Feuchtbaum; Partha Neogi; Thomson Ho; Leslie Gaffney; Robert J Currier
Journal:  Genet Med       Date:  2015-12-10       Impact factor: 8.822

  1 in total