Radiological assessment of a new bone densitometer--the Lunar EXPERT.

C F Njeh1, K Apple, D H Temperton, C M Boivin.   

Abstract

Dual energy X-ray absorptiometry (DXA) is one of the most widely used techniques in the management of osteoporosis and other skeletal diseases. Although patient doses from DXA are generally low, it is still necessary to measure them to assess the risk of radiation injury. We report on a study to estimate the effective dose (ED) to patients and staff from a new DXA scanner--the Lunar EXPERT, and make a comparison with a similar study carried out on a Lunar DPX-L. The entrance surface doses were measured to be 895 microGy and 10.25 microGy for the EXPERT and DPX-L, respectively. The EXPERT maximum EDs were calculated to be 74.7 microSv and 44.9 microSv for the anteroposterior (AP) lumbar spine and the proximal femur, respectively. More than 50% reduction in ED could be achieved by using a smaller scanning width. The maximum EDs for the DPX-L were calculated to be 0.21 microSv and 0.15 microSv for the AP lumbar spine and the proximal femur, respectively. The scattered dose rates (ambient dose equivalent) were measured to be less than 2 and less than 1 microSv h-1 at 50 cm and 100 cm, respectively, for the DPX-L, and the equivalent values for the EXPERT were 240 and 64 microSv h-1. Although both the patient dose and scattered dose rates are quite low relative to other radiological examinations, good practice aimed at dose reduction should still be implemented. Whilst protection for the operator is not needed for the DPX-L system, it may be (depending on the size of the room) for the EXPERT system.

Entities:  

Mesh:

Year:  1996        PMID: 8665133     DOI: 10.1259/0007-1285-69-820-335

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

Review 1.  Radiation exposure in X-ray-based imaging techniques used in osteoporosis.

Authors:  John Damilakis; Judith E Adams; Giuseppe Guglielmi; Thomas M Link
Journal:  Eur Radiol       Date:  2010-06-18       Impact factor: 5.315

2.  Total dose incurred by patients and staff from BMD measurement using a new 2D digital bone densitometer.

Authors:  V Boudousq; P O Kotzki; J M Dinten; C Barrau; C Robert-Coutant; E Thomas; D Mariano Goulart
Journal:  Osteoporos Int       Date:  2003-04-01       Impact factor: 4.507

3.  Estimating the absorbed dose to critical organs during dual X-ray absorptiometry.

Authors:  M Mokhtari-Dizaji; A A Sharafi; B Larijani; N Mokhlesian; H Hasanzadeh
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500