Literature DB >> 8661643

Fragmentation of pulmonary emboli: in vivo experimental evaluation of two high-speed rotating catheters.

T Schmitz-Rode1, G Adam, M Kilbinger, J Pfeffer, S B Günther.   

Abstract

PURPOSE: To test two over-the-wire systems for fragmentation of pulmonary emboli.
METHODS: In 11 dogs, 22 embolic occlusions of lobar or central pulmonary arteries were performed by injection of preformed emboli through a jugular vein sheath. A commercially available device (thrombolizer) and a modified version of the impeller catheter were introduced via the femoral vein and positioned at the embolus site.
RESULTS: Catheter placement at the site of the emboli was possible. In more than half of the cases a hydrophilic or an extra-stiff guidewire was necessary. The thrombolizer did not rotate properly with its original pneumatic drive and required a major modification. When sufficient rotation was provided, both fragmentation catheters were able to clear the occluded main arteries. Side branches were partly obstructed by the resulting fragments. Recanalization led to a reduction of the emboli-induced elevation of the pulmonary arterial pressure by two-thirds. Histology of the recanalized pulmonary artery segments revealed localized (impeller catheter) and widespread (thrombolizer) periarterial hemorrhage.
CONCLUSION: Embolus fragmentation led to a hemodynamic improvement. The impeller catheter was less traumatic compared with the thrombolizer, which was technically insufficient.

Entities:  

Mesh:

Year:  1996        PMID: 8661643

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  7 in total

1.  Simultaneous mechanical clot fragmentation and pharmacologic thrombolysis in acute massive pulmonary embolism.

Authors:  M Rafique; S Middlemost; J Skoularigis; P Sareli
Journal:  Am J Cardiol       Date:  1992-02-01       Impact factor: 2.778

2.  New device for percutaneous fragmentation of pulmonary emboli.

Authors:  T Schmitz-Rode; R W Günther
Journal:  Radiology       Date:  1991-07       Impact factor: 11.105

3.  Pulmonary embolism death rates.

Authors:  S Z Goldhaber
Journal:  Am Heart J       Date:  1988-06       Impact factor: 4.749

4.  Transvenous removal of pulmonary emboli by vacuum-cup catheter technique.

Authors:  L J Greenfield; G O Kimmell; W C McCurdy
Journal:  J Surg Res       Date:  1969-06       Impact factor: 2.192

5.  Percutaneous catheter fragmentation and distal dispersion of proximal pulmonary embolus.

Authors:  A J Brady; T Crake; C M Oakley
Journal:  Lancet       Date:  1991-11-09       Impact factor: 79.321

6.  Percutaneous fragmentation of pulmonary emboli in dogs with the impeller-basket catheter.

Authors:  T Schmitz-Rode; D Vorwerk; R W Günther; S Biesterfeld
Journal:  Cardiovasc Intervent Radiol       Date:  1993 Jul-Aug       Impact factor: 2.740

7.  Pulmonary embolectomy by catheter device in massive pulmonary embolism.

Authors:  J F Timsit; P Reynaud; G Meyer; H Sors
Journal:  Chest       Date:  1991-09       Impact factor: 9.410

  7 in total