Literature DB >> 8661586

Complications of inferior vena cava filters.

C E Ray1, J A Kaufman.   

Abstract

Mesh:

Year:  1996        PMID: 8661586     DOI: 10.1007/s002619900084

Source DB:  PubMed          Journal:  Abdom Imaging        ISSN: 0942-8925


× No keyword cloud information.
  10 in total

1.  The clinical use of an esophageal Doppler monitor for hemodynamic monitoring in sepsis.

Authors:  S R Eachempati; C Young; J Alexander; F D Cirisano; G C Rodriguez; R L Reed
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

2.  Successful Endovascular Removal of a Perforated Inferior Vena Cava Filter Complicated by a Large Retroperitoneal Hematoma: Pitfall of Catheter-Directed Thrombolysis.

Authors:  Norio Ishigami; Tomoo Nagai; Junko Arakawa; Hideki Hisadome; Hirotsugu Tabata
Journal:  Int J Angiol       Date:  2015-12-15

3.  Use of Prophylactic Inferior Vena Cava Filters in Trauma.

Authors:  Ahmed A Naiem; Alreem K Al-Hinai; Rashid Al-Sukaiti; Hani Al-Qadhi
Journal:  Sultan Qaboos Univ Med J       Date:  2016-02-02

Review 4.  Complications of inferior vena cava filters.

Authors:  Simer Grewal; Murthy R Chamarthy; Sanjeeva P Kalva
Journal:  Cardiovasc Diagn Ther       Date:  2016-12

5.  Tempofilter II implantation in patients with lower extremity fractures and proximal deep vein thrombosis.

Authors:  Wei Jia; Jianlong Liu; Xuan Tian; Peng Jiang
Journal:  Diagn Interv Radiol       Date:  2014 May-Jun       Impact factor: 2.630

6.  Rates and predictors of plans for inferior vena cava filter retrieval in hospitalized patients.

Authors:  John F Mission; Robert K Kerlan; Justin H Tan; Margaret C Fang
Journal:  J Gen Intern Med       Date:  2010-01-20       Impact factor: 5.128

7.  Hemorrhagic shock with delayed retroperitoneal hemorrhage after deployment of an inferior vena cava filter: report of a case.

Authors:  Kazunori Inuzuka; Naoki Unno; Naoto Yamamoto; Hiroshi Mitsuoka; Daisuke Sagara; Minoru Suzuki; Motohiro Nishiyama; Hiroyuki Konno
Journal:  Surg Today       Date:  2007-06-26       Impact factor: 2.549

8.  Fracture of a Tempofilter II: an initial case report.

Authors:  Hyung Jun Kim; Nam Kyu Chang; Jae Hoon Lim; Jae Kyu Kim
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500

9.  ANMCO Position Paper: long-term follow-up of patients with pulmonary thromboembolism.

Authors:  Carlo D'Agostino; Pietro Zonzin; Iolanda Enea; Michele Massimo Gulizia; Walter Ageno; Piergiuseppe Agostoni; Michele Azzarito; Cecilia Becattini; Amedeo Bongarzoni; Francesca Bux; Franco Casazza; Nicoletta Corrieri; Michele D'Alto; Nicola D'Amato; Andrea Maria D'Armini; Maria Grazia De Natale; Giovanni Di Minno; Giuseppe Favretto; Lucia Filippi; Valentina Grazioli; Gualtiero Palareti; Raffaele Pesavento; Loris Roncon; Laura Scelsi; Antonella Tufano
Journal:  Eur Heart J Suppl       Date:  2017-05-02       Impact factor: 1.803

10.  Incidental echocardiographic finding: Fractured inferior vena cava filter.

Authors:  Bhradeev Sivasambu; Deepa Kabirdas; Assad Movahed
Journal:  World J Clin Cases       Date:  2017-04-16       Impact factor: 1.337

  10 in total