Literature DB >> 8659766

A new method for continuous intramucosal PCO2 measurement in the gastrointestinal tract.

G Knichwitz1, J Rötker, T Brüssel, M Kuhmann, N Mertes, T Möllhoff.   

Abstract

Gastric tonometry has been introduced for the early detection of impaired splanchnic perfusion by determination of the intramucosal PCO2. However, due to methodological problems, i.e., instability of CO2 in water, to assess the exact intramucosal PCO2 with the nasogastric tonometer is unreliable. The present in vitro and in vivo study examines a new fiberoptic PCO2 sensor for the continuous determination of the intramucosal PCO2 and compares these data with that of conventional tonometry. In an in vitro experiment the fiberoptic PCO2 sensor was used to determine the PCO2 of water and humidified air with predefined CO2 values. In both media, predefined CO2 values (35, 42, 49 mm Hg) could be assessed exactly after 9 min of equilibration with a maximum deviation less than 3.5%. In contrast, the values obtained by conventional tonometry showed larger differences. In in vivo experiments on six pigs PCO2 differences were induced by ventilatory changes to validate the fiberoptic PCO2 sensor. Under anesthesia a laparotomy was performed, the ileum punctured, and the fiberoptic PCO2 sensor introduced into the ileal lumen. Arterial PCO2 (PaCO2), mesenteric venous PCO2 (PmvCO2), and intramucosal PCO2, (PiCO2) were determined during normoventilation, hypoventilation, and hyperventilation. During hypoventilation the PiCO2 increased from 53.8 +/- 2.0 mm Hg (PaCO2 = 39.8 +/- 1.4 mm Hg, PmvCO2 = 48.7 +/- 2.7 mm Hg) to 66.5 +/- 4.9 mm Hg (PaCO2 = 52.7 +/- 3.1 mm Hg, PmvCO2 = 62.4 +/- 5.7 mm Hg). With hyperventilation the PiCO2 decreased to 46.8 +/- 2.5 mm Hg (PaCO2 = 29.8 +/- 1.8 mm Hg, PmvCO2 = 41.8 +/- 2.7 mm Hg). The coefficient of correlation (r2) between PiCO2 and PaCO2 was 0.82, and between PiCO2 and PmvCO2 0.94. The fiberoptic PCO2 sensor can determine PiCO2 in a precise and reliable manner, and can continuously record fast intraluminar changes of CO2 in the ileum that were caused by ventilatory changes. The fiberoptic PCO2 sensor is the only method that reliably monitors PiCO2 in the gastrointestinal tract. By the direct measurement of PCO2 the methodological problems associated with the conventional nasogastric tonometry are abolished.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8659766     DOI: 10.1097/00000539-199607000-00003

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

Review 1.  Monitoring the hepato-splanchnic region in the critically ill patient. Measurement techniques and clinical relevance.

Authors:  A Brinkmann; E Calzia; K Träger; P Radermacher
Journal:  Intensive Care Med       Date:  1998-06       Impact factor: 17.440

2.  Subcutaneous gas tensions closely track ileal mucosal gas tensions in a model of endotoxaemia without anaerobism.

Authors:  Bala Venkatesh; Thomas J Morgan; Jonathan Hall; Zolton Endre; Desley Willgoss
Journal:  Intensive Care Med       Date:  2005-02-10       Impact factor: 17.440

Review 3.  [Intestinal malperfusion in critical care patients].

Authors:  G Knichwitz; C Kruse; H van Aken
Journal:  Anaesthesist       Date:  2005-01       Impact factor: 1.041

4.  Effect of combining nicotinamide as a PARS-inhibitor with selective iNOS blockade during porcine endotoxemia.

Authors:  A Stehr; F Ploner; I Tugtekin; M Matejovic; M Theisen; C Zülke; M Georgieff; P Radermacher; K-W Jauch
Journal:  Intensive Care Med       Date:  2003-05-09       Impact factor: 17.440

5.  Assessment of a new prototype hydrogel CO( 2 ) sensor; comparison with air tonometry.

Authors:  Rinze W F ter Steege; Sebastiaan Herber; Wouter Olthuis; Piet Bergveld; Albert van den Berg; Jeroen J Kolkman
Journal:  J Clin Monit Comput       Date:  2006-12-19       Impact factor: 1.977

6.  Esophageal capnometry during hemorrhagic shock and after resuscitation in rats.

Authors:  Balagangadhar R Totapally; Harun Fakioglu; Dan Torbati; Jack Wolfsdorf
Journal:  Crit Care       Date:  2002-12-20       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.