Literature DB >> 8659426

Assessment of a technology that permits individualized scan delays on helical hepatic CT: a technique to improve efficiency in use of contrast material.

P M Silverman1, S C Roberts, I Ducic, M C Tefft, M C Olson, C Cooper, R K Zeman.   

Abstract

OBJECTIVE: We performed this study to assess the usefulness of a computer automated scan technology (CAST) for individualizing scan delay during helical CT to improve the efficiency of hepatic enhancement. SUBJECTS AND METHODS: We prospectively evaluated 183 patients who were randomized into five groups. Control patients received 100 or 150 ml of contrast material (320 mg I/ml) with a 60-sec delay between contrast injection at 3 ml/sec and scanning. CAST patients received 100, 125, or 150 ml. In our latter groups we used an hepatic enhancement threshold of 50 H over baseline to determine the optimum delay between contrast injection and scanning. For the intergroup comparisons, we measured the liver on baseline and enhanced helical CT scans at the upper, mid, and lower levels of the liver.
RESULTS: The mean enhancement in patients who received 150 ml of contrast material was 70.7 +/- 19.4 H for the control group and 81.0 +/- 17.5 H for the CAST group (p < .05). Hepatic enhancement above 50 H was achieved in 84% of the control subjects compared with 100% of CAST subjects; more than 60 H hepatic enhancement was achieved in 73% of control subjects and in 89% of CAST subjects. The use of CAST software with 125-ml contrast doses provided enhancement equivalent to that of control subjects who received 150 ml of contrast material (mean enhancement in CAST subjects, 70.3 +/- 15.4 H). Enhancement above 50 H was reached in 98% of CAST and 84% of control patients. With 100 ml of contrast material, 24% of patients failed to initiate CAST, resulting in enhancement similar to control patients (CAST, 54.2 +/- 11.4 H; controls, 56.9 +/- 15.2 H).
CONCLUSION: Using a contrast dose of 150 ml, CAST provided significantly increased hepatic enhancement than that achieved in control subjects with less variability. For equivalent hepatic enhancement, contrast doses could be decreased by 25 ml using CAST technology because it provides individualized scan delays.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8659426     DOI: 10.2214/ajr.167.1.8659426

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  Real-time bolus-triggering technique in helical CT: efficacy in identifying inflow vein thrombosis.

Authors:  R Kickuth; J Kirchner; U Laufer; D Liermann
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

2.  Standardisation of liver MDCT by tracking liver parenchyma enhancement to trigger imaging.

Authors:  H Brodoefel; A Tognolini; G A Zamboni; S Gourtsoyianni; C D Claussen; V Raptopoulos
Journal:  Eur Radiol       Date:  2011-11-05       Impact factor: 5.315

3.  Volumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model.

Authors:  Shinichiro Mori; Takayuki Obata; Naoshi Nakajima; Nobutsune Ichihara; Masahiro Endo
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

4.  Study of an adaptive bolus chasing CT angiography.

Authors:  Er-Wei Bai; James R Bennett; Robert McCabe; Melhem J Sharafuddin; Henri Bai; John Halloran; Michael Vannier; Ying Liu; Chenglin Wang; Ge Wang
Journal:  J Xray Sci Technol       Date:  2006       Impact factor: 1.535

5.  Utility of arterial phase of dynamic CT for detection of intestinal ischemia associated with strangulation ileus.

Authors:  Gaku Ohira; Kiyohiko Shuto; Tsuguaki Kono; Takayuki Tohma; Hisashi Gunji; Kazuo Narushima; Shunsuke Imanishi; Takeshi Fujishiro; Tohru Tochigi; Toshiharu Hanaoka; Hideaki Miyauchi; Naoyuki Hanari; Hisahiro Matsubara; Noriyuki Yanagawa
Journal:  World J Radiol       Date:  2012-11-28

6.  Liver metastases: imaging considerations for protocol development with multislice CT (MSCT).

Authors:  Paul M Silverman
Journal:  Cancer Imaging       Date:  2006-11-08       Impact factor: 3.909

7.  Bolus characteristics based on Magnetic Resonance Angiography.

Authors:  Zhijun Cai; Alan Stolpen; Melhem J Sharafuddin; Robert McCabe; Henri Bai; Tom Potts; Michael Vannier; Debiao Li; Xiaoming Bi; James Bennett; Jafar Golzarian; Shiliang Sun; Ge Wang; Er-Wei Bai
Journal:  Biomed Eng Online       Date:  2006-10-17       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.