Literature DB >> 8653954

Semiextended position of intramedullary nailing of the proximal tibia.

P Tornetta1, E Collins.   

Abstract

Over a 24 month period, 30 patients with proximal tibia fractures who were reviewed consecutively were treated by nonreamed, statically locked, intramedullary nailing. There were 16 open, 13 segmental, and 7 comminuted fractures (Winquist III, IV). The average distance from the fracture to the proximal locking screws was 24 mm (range, 0-65 mm). All procedures were performed while the patient's affected leg was on a radiolucent table without traction. The last 25 fractures were nailed using a partial (2/3) medial parapatellar incision while the leg was semiextended. This approach allowed the patella to be subluxed laterally availing the trochlear groove for use as a conduit for nail placement. Using only 15 degrees knee flexion eliminated the extension force of the quadriceps on the proximal fragment, which otherwise would have tended to cause anterior angulation at the fracture site. In the first 5 patients, the average anterior angulation was 8 degrees (range, 5 degrees-15 degrees). Of the 25 patients who were treated while in the semiextended position, none had more than 5 degrees anterior angulation and 19 had no anterior angulation. Fractures of 3 of the 25 patients had greater than 5 degrees angulation in the coronal plane, 2 of which were nailed in the semiextended position. This technique greatly facilitates intramedullary nailing of proximal tibia fractures.

Entities:  

Mesh:

Year:  1996        PMID: 8653954     DOI: 10.1097/00003086-199607000-00029

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  [Suprapatellar approach to tibial medullary nailing with electromagnetic field-guided distal locking].

Authors:  J M Rueger; A H Rücker; M Hoffmann
Journal:  Unfallchirurg       Date:  2015-04       Impact factor: 1.000

2.  Freehand 'figure 4' technique for tibial intramedullary nailing: introduction of technique and review of 87 cases.

Authors:  J Granville-Chapman; S Z Nawaz; A Trompeter; K J Newman; D S Elliott
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-09-08

Review 3.  Intramedullary nailing of tibial shaft fractures in the semi-extended position using a suprapatellar portal technique.

Authors:  Boris A Zelle
Journal:  Int Orthop       Date:  2017-03-30       Impact factor: 3.075

4.  "Clothesline technique" for proximal tibial shaft fracture fixation using conventional intramedullary nail: a simple, useful, and inexpensive technique to prevent fracture malalignment.

Authors:  William Dias Belangero; Robinson Esteves Santos Pires; Bruno Livani; Felipe Lins Rossi; Andre Luis Lugnani de Andrade
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-23

5.  [Risk of iatrogenic neurovascular damage by proximal 3-dimensional intramedullary nailing of the tibia].

Authors:  M Hansen; P Roux; J Adolph; J Blum
Journal:  Unfallchirurg       Date:  2010-06       Impact factor: 1.000

6.  [Intramedullary nailing of proximal tibial fractures. Complications and risk factors].

Authors:  C Josten; B Marquass; C Schwarz; A Verheyden
Journal:  Unfallchirurg       Date:  2010-01       Impact factor: 1.000

7.  [Nailing of metaphyseal fractures].

Authors:  P M Rommens; P Pairon; S Kuhn
Journal:  Unfallchirurg       Date:  2013-09       Impact factor: 1.000

8.  Intramedullary nailing of femoral and tibial shaft fractures.

Authors:  George W Wood
Journal:  J Orthop Sci       Date:  2006-12-04       Impact factor: 1.601

9.  Biomechanical comparison of six intramedullary nails, for the treatment of ex-tra-articular, proximal tibial fractures.

Authors:  G Gkouvas; F Agathangelidis; C Nakas; C David; D Sagris; G Petsatodis
Journal:  Hippokratia       Date:  2019 Apr-Jun       Impact factor: 0.471

10.  Open fractures of the tibia in the pediatric population: a systematic review.

Authors:  Keith D Baldwin; Oladapo M Babatunde; G Russell Huffman; Harish S Hosalkar
Journal:  J Child Orthop       Date:  2009-04-03       Impact factor: 1.548

View more