Estimating exposure intensity in an imperfectly mixed room.

M Nicas1.   

Abstract

The well-mixed room model is traditionally used to predict the concentration of contaminants in indoor environments. To account for imperfect air mixing, the room supply/exhaust air rate Q is frequently multiplied by a mixing factor m, where 0 < m < or = 1, and an effective ventilation rate QE = m . Q is used in place of Q in the well-mixed room equations. However, this procedure is inappropriate because a well-mixed room model, albeit with an adjusted ventilation rate, is still used to describe an imperfectly mixed room. To illustrate the errors that may result, a two-zone model is described in which a room is conceptually divided into an upper zone and lower zone, where the latter is the zone of occupancy. Air is supplied to and exhausted from the upper zone at rate Q, and air exchanges between the two zones at rate beta. The lower zone's true ventilation rate is termed its purging flow rate QL, where QL = [beta/(beta + Q)]Q. Expressions for the steady-state contaminant levels in the two zones and for decay from the steady-state levels are presented. In a two-zone room, if one ignores imperfect air mixing and attempts to estimate QE from a decay curve, QE will usually be greater than QL. Given that contaminant is emitted in the lower zone, subsequent use of QE rather than QL to predict steady-state exposure intensity in the room will cause an underestimation error. For a room with an upper- to lower-zone volume ratio of 2:3, the underestimation error can reach 40%. If a room has a single or dominant point source of contaminant, it is recommended that the purging flow rate near the release point be determined, which permits a more accurate prediction of a worker's exposure intensity near the source. Alternative methods for determining the local purging flow rate are described. It is also shown that age-of-air analysis techniques do not provide information directly relevant to estimating exposure intensity.

Mesh:

Year:  1996        PMID: 8651074     DOI: 10.1080/15428119691014756

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  10 in total

1.  Rapid immunoassays for detection of UV-induced cyclobutane pyrimidine dimers in whole bacterial cells.

Authors:  Jordan Peccia; Mark Hernandez
Journal:  Appl Environ Microbiol       Date:  2002-05       Impact factor: 4.792

2.  Bayesian modeling of exposure and airflow using two-zone models.

Authors:  Yufen Zhang; Sudipto Banerjee; Rui Yang; Claudiu Lungu; Gurumurthy Ramachandran
Journal:  Ann Occup Hyg       Date:  2009-04-29

3.  Cross-classified occupational exposure data.

Authors:  Rachael M Jones; Igor Burstyn
Journal:  J Occup Environ Hyg       Date:  2016-09       Impact factor: 2.155

4.  Bayesian Modeling for Physical Processes in Industrial Hygiene Using Misaligned Workplace Data.

Authors:  João V D Monteiro; Sudipto Banerjee; Gurumurthy Ramachandran
Journal:  Technometrics       Date:  2013-09-06

5.  Model Predictions of Occupational Exposures to Diacetyl and 2,3-Pentanedione Emitted From Roasted Whole Bean and Ground Coffee: Influence of Roast Level and Physical Form on Specific Emission Rates.

Authors:  Ryan F LeBouf; Anand Ranpara; Elizabeth Fernandez; Dru A Burns; Alyson R Fortner
Journal:  Front Public Health       Date:  2022-03-23

6.  Modeling Clothing as a Vector for Transporting Airborne Particles and Pathogens across Indoor Microenvironments.

Authors:  Jacob Kvasnicka; Elaine A Cohen Hubal; Jeffrey A Siegel; James A Scott; Miriam L Diamond
Journal:  Environ Sci Technol       Date:  2022-04-11       Impact factor: 11.357

Review 7.  Evaluating the Theoretical Background of STOFFENMANAGER® and the Advanced REACH Tool.

Authors:  Antti Joonas Koivisto; Michael Jayjock; Kaarle J Hämeri; Markku Kulmala; Patrick Van Sprang; Mingzhou Yu; Brandon E Boor; Tareq Hussein; Ismo K Koponen; Jakob Löndahl; Lidia Morawska; John C Little; Susan Arnold
Journal:  Ann Work Expo Health       Date:  2022-04-22       Impact factor: 2.779

8.  Zonal modeling of air distribution impact on the long-range airborne transmission risk of SARS-CoV-2.

Authors:  Amar Aganovic; Guangyu Cao; Jarek Kurnitski; Arsen Melikov; Pawel Wargocki
Journal:  Appl Math Model       Date:  2022-08-28       Impact factor: 5.336

Review 9.  Integrating human indoor air pollutant exposure within Life Cycle Impact Assessment.

Authors:  Stefanie Hellweg; Evangelia Demou; Raffaella Bruzzi; Arjen Meijer; Ralph K Rosenbaum; Mark A Huijbregts; Thomas E Mckone
Journal:  Environ Sci Technol       Date:  2009-03-15       Impact factor: 9.028

10.  Application of mathematical models in combination with Monte Carlo simulation for prediction of isoflurane concentration in an operation room theater.

Authors:  Mohammad Javad Zare Sakhvidi; Abolfazl Barkhordari; Maryam Salehi; Shekoofeh Behdad; Hossein Fallahzadeh
Journal:  Ind Health       Date:  2013-08-02       Impact factor: 2.179